- 8 -
Ű
3. Functions
3-1. 13:1 pump unit
D: EMERGENCY VALVE
EMERGENCY STOP
POSITION
OPERATING
POSITION
A
B
C
D
E
F
H
G
G: CIRCULATION VALVE
OPEN POSITION
CLOSE POSITION
AIR INLET
AIR OUTLET
FOR SPRAY GUN
FLUID OUTLET
Fig.1: Functions (13:1 pump unit)
Parts
Function
A
Plunger Pump
PP-7131N, stainless steel model
B
Pop-off Valve
Working pressure: 116psi
C
Air Regulator
For pump operation. with locking knob feature
D
Emergency Valve
Emergency air shut off valve
E
Suction Hose Set
with 50mesh filter
F
Air Filter Regulator
For atomizing air wth locking knob feature
G
Circulation Valve
To circulate or dump fluid
H
Circulation Tube
To circulate or dump fluid
I
Fluid Filter Set (Option)
100mesh
*Spray gun and fluid and air hoses are not included in this unit.
Summary of Contents for MSU-111N