- 6 -
Ű
2. Specifications
2-2. Performance curve
PP-7131N (13:1 pump)
PP-1171CNE (17:1 pump)
Inlet air pressure: The number with each curve
Test fluid: Water
How to find fluid pressure
1. Locate specific fluid output along the horizontal axis of the chart.
2. Follow vertical to the intersection with the fluid pressure curve of
selected inlet air pressure.
3. Follow left to the vertical axis of the chart to read fluid pressure.
How to find air consumption
1. Locate specific fluid out put along the horizontal axis of the chart.
2. Follow vertical to the intersection with the air consumption curve of
selected inlet air pressure.
3. Follow right to the vertical axis of the chart to read air consumption.
How to find cycle per minutes
1. Locate specific fluid output along the horizontal axis of the chart.
2. Follow vertical to the intersection with number of cycle curve of top chart.
Follow left to the vertical axis of the chart to read cycle per minutes.
Example: PP7131N (13:1 pump)
See example to right Fig. A
When inlet air pressure is 71psi and fluid output is 0.3gal/min,
1. Fluid pressure is approx. 700psi
2. Air consumption is approx. 5.5cfm.
3. Cycle per minutes is approx. 60 cycles/min.