6
-
4.2 Precautions on installation and handling of low voltage cable
Be sure to read and observe the below cautions before connection, installing and handling low voltage
cable.
CAUTION
(1) Tighten cap nut of low voltage cable and securely connect low voltage cable.
If tightening is incomplete, paint and solvent can enter inside of connector causing failure of electrostatic gun and
electrostatic controller.
(2) Be sure to observe the following about binding low voltage cable of electrostatic gun in order to maintain its
strength and durability.
①
Never bind cable within about 50cm from gun handle of electrostatic gun.
②
When pointing electrostatic gun upwards, downwards, left and right, carefully bind low voltage cable with air
hose and fluid hose so that there is no strong bend or tension on low voltage cable.
③
When binding over 50cm from gun handle, bind with attached spiral tube or vinyl tape at over 5cm intervals,
and do not bind too tightly. Especially do not bind continuously with vinyl tape or wide spiral tube. If done, bound
section becomes like a hard bar, and it is broken at both ends, then it can cause disconnection or damage of
cable and hose.
(3) Do not bind low voltage cable, air hose or fluid hose, or handle electrostatic gun so that there is forced bend or
strong tension during painting.. If done, it can reduce strength and cause disconnection.
(4) Pay attention not to trample on low voltage cable. It can disconnect when you trample on it especially on grid floor
of the spray booth.
(5) Do not continuously bind low voltage cable itself (especially near electrostatic gun connector) with vinyl tape etc., to
increase strength or avoid dirt. If done, it can conversely reduce strength and cause disconnection.
(6) Do not immerse low voltage cable in solvent or paint for a long time. If done, it can greatly reduce strength and
lifetime of low voltage cable.
(7) After cleaning low voltage cable, be sure to remove solvent attached to surface, or blow with air.
(8) Do not use metallic binding band. Metallic one can accumulate static electricity and cause electric shock.
Low voltage cable
Bind low voltage cable lighter
than air hose and fluid hose so
that there is no strong tension
on low voltage cable when
inclining gun up or down
Over 5cm intervals from
50cm distance
Tension can cause
bend
(can
be
disconnected)
Low voltage cable
Do not bind continuously
with vinyl tape or with
spiral tube like this.
About
Summary of Contents for E-M10C Series
Page 1: ...E M15C E M10C E spray Series...
Page 2: ......
Page 3: ...1 1 1 E SC12B A 10 A...
Page 4: ...E SC12B E M10C P P 8 E M10C E SC12B OFF E M10C 30cm 30cm 30cm...
Page 5: ...P 1 1 OFF E SC12B E M10C 30cm E M10C OFF OFF OFF OFF 2 3 30cm 30cm 30cm...
Page 6: ...B A 10 5 10 8 JIS T 8103 JIS T 8118 OFF...
Page 7: ...P 12 3 P 10 11 P 5...
Page 8: ...1 1 2 3 4 5 6 7 8 9...
Page 10: ...3 2 E M15C E M10C...
Page 11: ...4 E M15C E M10C G3 8 AC 12V G1 4 G3 8 AC 12V G1 4...
Page 12: ...5 3 cm cm...
Page 14: ...7 E M15C E M15C AHU 8 10m PHN 6 10m AC 100V AHU 8 5m E SC 10 G3 8 G1 4 G1 4 DPS 90 G3 8...
Page 16: ...9 1 E SC12B 200 300mm...
Page 17: ...10 E SC12B OFF E SC12B OFF 1 2 P 17 3...
Page 18: ...11 1...
Page 19: ...12 1 E SC12B 1 P 10 11 No 8 1 P 26 8 1 P26 8 2 P 27 5 1 2 No 1 P12 4 1 P 5 No...
Page 22: ...15 A M 500V 1 V M 500V 1 V 2000M 180 280M...
Page 23: ...16 E SC12B 1 2 DC V 40kV MAX ON DC 11 5 12 5V EBC 12S7...
Page 24: ...17 4 1 E SC12B 1 1 2 3 4 1 2 1...
Page 25: ...18 2 2 1 2 M2X0 4 1...
Page 26: ...19 2 3 1 2 30 1 3...
Page 27: ...20 2 3 1 2 20...
Page 28: ...21 1 2 mm...
Page 29: ...22 E M15C 2 E M10C 2...
Page 30: ...23...
Page 33: ...26 8 No 1...
Page 34: ...27 No 30M cm E SC B...
Page 35: ...28 No...