9. CHECK WEIGHING FUNCTIONS
Check weighing separates the weight values into a maximum of five stages.
Select a weighing mode (CALF-14) from the following.
9.1. Check Weighing 1
When the weight value is compared with the setpoint and the condition is met, the control output turns ON.
Condition
Control output
Gross value
Near-zero
Near-zero
Weight value > Hi-Hi limit
Hi-Hi
Weight value > Target
+
Hi limit
Hi
Target
+
Hi limit
Weight value
Target
-
Lo limit
Go
Weight value < Target
-
Lo limit
Lo
Weight value < Lo-Lo limit
Lo-Lo
9.2. Check Weighing 2
When the weight value is compared with the setpoint and the condition is met, the control output turns ON.
Condition
Control output
Gross value
Near-zero
Near-zero
Weight value > Target
+
Hi-Hi limit
Hi-Hi
Target
+
Hi-Hi limit
Weight value > Target
+
Hi limit
Hi
Target
+
Hi limit
Weight value
Target
-
Lo limit
Go
Target
-
Lo limit > Weight value
Target
-
Lo-Lo limit
Lo
Weight value < Lo-Lo limit
Lo-Lo
9.3. Check Weighing 3
When the weight value is compared with the setpoint and the condition is met, the control output turns ON.
Condition
Control output
Gross value
Near-zero
Near-zero
Weight value > Hi-Hi limit
Hi-Hi
Weight value > Hi limit
Hi
Hi limit
Weight value
Lo limit
Go
Weight value < Lo limit
Lo
Weight value < Lo-Lo limit
Lo-Lo