![AND AD-4401A Instruction Manual Download Page 20](http://html.mh-extra.com/html/and/ad-4401a/ad-4401a_instruction-manual_2941307020.webp)
AD-4401A Page
18
Timing chart
Final weight
Free fall
Preliminary
Optional
Preliminary
Near-zero
Gross value
Net value
Near-zero output
Large flow output
Medium flow output
Small flow output
Weighing start input
Weighing end output
OK/Over/Under output
Discharge start input
Discharge output
T1: Weighing start input delay time
T2: Large flow comparison disable time
T3: Medium flow comparison disable time
T4: Small flow comparison disable time
T5: Judging delay time
T6: Weighing end output time
T7: Discharge start input delay time
T8: Discharge end delay time
Overweight
Underweight
T1
T2
T3
T4
T5
T6
T7
T8