Chapter 7 : REMOTE CONTROL PROGRAMMER'S GUIDE (continued)
NATIX™
PAGE 46
7-4. COMMANDS AND RESPONSES TABLE (continued)
VALUE
ASCII
COMMAND
RESPONSE
COMMAND
DESCRIPTION
TYPE
MIN MAX
DESCRIPTION
CONTROLS COMMANDS
ja
TALA
Input number for TALLY1
Rd/Wr
1
7
jb
TALB
Input number for TALLY2.
Rd/Wr
1
7
jc
TALC
Input number for TALLY3.
Rd/Wr
1
7
0 = input #1.
.......
7 = input #8.
JA TAON
TALLY1
status.
Rd
0
1
0 = TALLY1 inactive
1 = TALLY1 active.
JB TBON
TALLY2
status.
Rd
0
1
0 = TALLY2 inactive
1 = TALLY2 active.
JC TCON
TALLY3
status.
Rd
0
1
0 = TALLY3 inactive
1 = TALLY3 active.
QE
EPD
2:2 pull down correction.
Rd/Wr
0
1
0 = off
1 = auto.
ye
EPOS
Erase all memories.
Rd/Wr
0
1
1 = erase all memories (automatic reset).
yd DEMO
Demo
mode.
Rd/Wr
0
1
0 = demo mode inactive.
1 = demo mode active.
yi
EISP
Auto-lock
Rd/Wr
0
1
0 = off
1 = on.
fr
BFCR
Red level adjustment of the FADE.
Rd/Wr
0
255
fb
BFCB
Blue level adjustment of the FADE.
Rd/Wr
0
255
OUT 1
fg
BFCG
Green level adjustment of the FADE.
Rd/Wr
0
255
fR
bfcr
Red level adjustment of the FADE.
Rd/Wr
0
255
fB
bfcb
Blue level adjustment of the FADE.
Rd/Wr
0
255
OUT 2
fG
bfcg
Green level adjustment of the FADE.
Rd/Wr
0
255
xI I_
Identification
number.
Rd
0 65535
xK
K_
"K" Firmware Version.
Rd
0 65535
xE
E_
"E" Firmware Version.
Rd
0 65535
xF
F_
"F" Firmware Version.
Rd
0 65535
xP
P_
"P" Firmware Version.
Rd
0 65535
xV
V_
"V" Firmware Version.
Rd
0 65535
Values displayed in hexadecimal in the device.
xU VERU
Update
version.
Rd
0 65535 Example: VERU104 = version 1.4
Y
FRES
DEFAULT VALUE.
Rd/Wr
0
1
1 = Default value action (automatic reset).
OTHERS COMMANDS
N TBP
T-BAR
position.
Rd/Wr
0
255
ub
TBA
Executed percentage of the effect.
Rd
0
16383 0 = 0%
16383 = 100%
uv TBAV
T-BAR
availability.
Rd
0
1
0 = T-BAR unavailable. 1 = T-BAR available.
? DEV
Device
type.
Rd
0
65535 31 = NTX8022A.
#
#1,....#0 Send all device parameters.
Rd
NOTE:
(
M
) = output 1.
Rd/Wr = Read and write command.
(
P
) = output 2.
Rd
= Read only command.