Metering Menu 

Selecting the 

Metering Functions

 option under 

MAIN MENU 

opens the secondary metering menu window shown in Figure 46.  

08600-

048

 

Figure 46. Metering Menu 

From this window, many of the energy metering functions can be 
evaluated. Clicking each of the options shown under 

METERING 

MENU

 opens a new window in front of the metering menu 

window. Clicking the 

EXIT

 button in the new window brings 

you back to the metering menu window. From 

METERING 

MENU

, you can return to the main menu window by clicking 

the 

BACK to Main Menu 

option. Opening or closing new 

windows does not cause the ADE71xx/ADE75xx registers to reset.  
The 

Interrupt Registers

 window allows you to set up the inter-

rupt masks and view the status bits described in the ADE71xx/ 
ADE75xx data sheet. The 

Power Quality Information

 window 

allows you to read the registers associated with the current and 
voltage readings, along with monitoring the voltage channel 
frequency, zero crossings, and line voltage sag events. The offset 
calibration registers can be written to in the 

Offsets

 window. In 

all windows, any changes made are not written to the part until 
the corresponding 

WRITE

 button is clicked. 

Active, Reactive, and Apparent Energy 

The 

Active Energy

Reactive Energy

,

 

and 

Apparent Energy

 

options allow you to view the data path for each of these measure-
ments. The data path for the active energy data path is shown in 
Figure 47. 

08600-

049

 

Figure 47. Active Energy Window 

Similar windows are available for the 

Reactive Energy

 and 

Apparent Energy

 data paths. From these windows, the data 

paths can be configured and reset by writing to the necessary 
registers. Changes made on the data path window are not 
written to the part until the 

WRITE CONFIG

 button is clicked. 

The energy data can also be read in either normal mode or line 
cycle accumulation mode.  
From the active energy, reactive energy, and apparent energy 
windows, the calibration frequency output can be configured 
using the 

CF CFG

 button. Clicking this button opens the 

window shown in Figure 48. 

08600-

050

 

Figure 48. Calibration Frequency 

The two CF outputs can be configured and enabled from this 
window. Once again, any changes made in the window are not 
written to the part until the 

WRITE CF REGISTERS

 button is 

clicked. 
 
 

Summary of Contents for UG-061

Page 1: ...led EVAL ADE5169EBZ 2 comes with ADE5169 IC installed DOCUMENTS NEEDED ADE7116 ADE7166 ADE7169 ADE7566 ADE7569 data sheet ADE5166 ADE5169 ADE5566 ADE5569 data sheet SOFTWARE NEEDED PC based evaluation...

Page 2: ...o UART Board ADE8052Z DWDL1 Driver 12 Finding Assigned COM Port Number 13 Removing the Drivers 13 HyperTerminal Communication 14 IAR Kickstart Tools 15 Installing the IAR Kickstart Tools 15 Creating a...

Page 3: ...in emulator connector three push buttons and a prototype area Evaluation Kit CD CD containing all associated software and support documentation for the evaluation kit 9 V DC Power Adapter 220 V and 11...

Page 4: ...ftware An additional LabVIEW program is provided to work with the ADE51xx ADE55xx energy metering IC IAR KickStart1 Embedded Workbench KickStart version IAR Embedded Workbench KickStart version featur...

Page 5: ...s of this user guide When the procedures in Figure 3 have been followed and the evaluation board is operational the energy metering IC can be evaluated using the accompanying LabVIEW evaluation softwa...

Page 6: ...n the PC Prior to using the USB to UART board the driver must be installed See the Installing the Drivers section for full details on the installation procedure SAFETY Exercise caution when connecting...

Page 7: ...lters before being presented to the analog inputs of the energy metering IC CURRENT SENSE INPUTS P11 P11 is a three way connection block that allows the ADE71xx ADE75xx ADE51xx ADE55xx to be connected...

Page 8: ...he software supplied with the ADE7169 ADE5169 evaluation board allows user adjustment of the phase calibra tion register See the Evaluation Board Software section for more information The maximum anal...

Page 9: ...reduce the loop area which in turn reduces antenna effects A connection for the common mode voltage can be made at the connection point for the current carrying conductor For an antitamper configurati...

Page 10: ...the analog input VN is connected to AGND via the antialias filter R14 C15 Jumper JP9 should be left open The voltage attenuation network is made up of R12 R13 and R15 The maximum signal level permiss...

Page 11: ...e using internal charge pump Voltage Channel Input JP4 JP5 JP6 and JP9 open Using the on board resistor divider network for voltage attenuation Current Channel Input JP1 JP11 JP13 JP14 JP16 and JP19 o...

Page 12: ...gure 10 USB2UART Found 2 Click the Install from a list or specific location Advanced option and then click Next 3 Select Include this location in the search and use the Browse button to locate the Dri...

Page 13: ...ager under Windows using the following steps 1 Click the Start button located at the bottom left hand corner of the desktop 2 Select Control Panel then System to open the System Properties window 3 Se...

Page 14: ...a name for the new connection 3 Click OK 4 In the Connect Using drop down box select the COM port that the USB cable is connected to and click OK 5 On the properties window select 9600 as the baud ra...

Page 15: ...Software Installations option 4 Click the KickStart Edition option shown in Figure 19 08600 021 Figure 19 IAR Software Installation 5 A series of windows appears with installation options Select the...

Page 16: ...templates folder by clicking the symbol next to the folder 5 Expand the Analog Devices folder by clicking the symbol next to the folder A list of Analog Devices products appears see Figure 23 08600 0...

Page 17: ...Target Selection The default project settings of the ADE7169Fxx and ADE5169Fxx C and assembly templates configure the project to execute in an ADE7169Fxx or ADE5169Fxx target If this is not desired t...

Page 18: ...cause the IAR protocol is not supported Creating a Hexadecimal File The user can configure the project options so that IAR gene rates a hexadecimal file each time the project is built This hexadecimal...

Page 19: ...releasing the RESET push button S3 The SDEN 08600 033 push button S2 should then be released Once in serial download mode click the Find Device and Reset button on the serial downloader interface The...

Page 20: ...anges made to the flash protection should be written to the part using the WRITE command Note that when the WRITE button is clicked the flash memory is directly modified and therefore once a page has...

Page 21: ...Alternatively select ADE51xxFxx Eval Software and then ADE51xxFxx_eval_softare for the ADE51xx ADE55xx evaluation software REMOVING THE EVALUATION SOFTWARE The ADE71xx ADE75xx ADE51xx ADE55xx evaluat...

Page 22: ...e or voltmeter to probe both the VDD and VINTD pins Ensure that the USB to UART board connects to the P2 header and the necessary drivers are installed see the Installing the Drivers section To verify...

Page 23: ...iew the block diagram of the power sources to the ADE71xx ADE75xx in the power management window This window is shown in Figure 44 08600 046 Figure 44 Power Management Window The user can view or chan...

Page 24: ...ibration registers can be written to in the Offsets window In all windows any changes made are not written to the part until the corresponding WRITE button is clicked Active Reactive and Apparent Ener...

Page 25: ...METERING MENU Figure 49 shows the waveform sampling window 08600 051 Figure 49 Waveform Sampling Window The waveform sampling window allows you to view multiple waveforms in the signal chain including...

Page 26: ...ALL R48 R47 DO NOT INSTALL DO NOT INSTALL R46 DO NOT INSTALL R45 CLKIN CLKOUT 3 1 4 2 VR1 ZSR330GTA 1 3 2 4 Y2 32 768KHZ VDD1 VUART VSWOUT VSWOUT 0 1UF C32 VSWOUT BCTRL INT1 P0 0 R54 1K INT0B 1K R53 A...

Page 27: ...Evaluation Board User Guide UG 061 Rev 0 Page 27 of PCB LAYOUT COMPONENT PLACEMENT 08600 054 Figure 51 Silkscreen...

Page 28: ...UG 061 Evaluation Board User Guide Rev 0 Page 28 of PCB LAYOUT COMPONENT SIDE 08600 055 Figure 52 Layer 1...

Page 29: ...Evaluation Board User Guide UG 061 Rev 0 Page 29 of PCB LAYOUT SOLDER SIDE 08600 056 Figure 53 Layer 2...

Page 30: ...tion SMD header 0 100 Samtec TSM 122 01 T SV 1 P13 Vertical 3 position SMD header 0 100 Samtec TSM 133 01 T SV 1 P14 Right angle 3 position 0 100 tin connector Digi Key A19461 ND 1 P15 50 position hea...

Page 31: ...Evaluation Board User Guide UG 061 Rev 0 Page 31 of 3 NOTES...

Page 32: ...on or use of evaluation boards Information furnished by Analog Devices is believed to be accurate and reliable However no responsibility is assumed by Analog Devices for its use nor for any infringeme...

Page 33: ...Mouser Electronics Authorized Distributor Click to View Pricing Inventory Delivery Lifecycle Information Analog Devices Inc EVAL ADE5169EBZ 2 EVAL ADE7169EBZ 2...

Reviews: