Evaluation Board User Guide
UG-061
Rev. 0 | Page 25 of
Waveform Sampling
The waveform sampling window is accessible from the active
energy, reactive energy, and apparent energy windows and by
selecting the
Line Accumulation
option under
METERING
MENU
. Figure 49 shows the waveform sampling window.
08600-
051
Figure 49. Waveform Sampling Window
The waveform sampling window allows you to view multiple
waveforms in the signal chain, including the current, voltage,
active, reactive and apparent multiplier outputs, along with the
output of the IRMS LPF. The samples are taken at a speed of
3.2 kSPS. The number of samples is defined by adjusting the
value in the
Buffer Length
box.