background image

AMX Limited Warranty and Disclaimer

This Limited Warranty and Disclaimer extends only to products purchased directly from AMX or an AMX Authorized Partner which 
include AMX Dealers, Distributors, VIP’s or other AMX authorized entity.

AMX warrants its products to be free of defects in material and workmanship under normal use for three (3) years from the date of 
purchase, with the following exceptions:

Electroluminescent and LCD Control Panels are warranted for three (3) years, except for the display and touch overlay compo-
nents are warranted for a period of one (1) year.

Disk drive mechanisms, pan/tilt heads, power supplies, and MX Series products are warranted for a period of one (1) year.

AMX lighting products are guaranteed to switch on and off any load that is properly connected to our lighting products, as long 
as the AMX lighting products are under warranty. AMX also guarantees the control of dimmable loads that are properly con-
nected to our lighting products. The dimming performance or quality there of is not guaranteed, impart due to the random combi-
nations of dimmers, lamps and ballasts or transformers.

AMX software is warranted for a period of ninety (90) days.

Batteries and incandescent lamps are not covered under the warranty.

AMX AutoPatch Epica, Modula, Modula Series4, Modula CatPro Series and 8Y-3000 product models will be free of defects in 
materials and manufacture at the time of sale and will remain in good working order for a period of three (3) years following the 
date of the original sales invoice from AMX. The three-year warranty period will be extended to the life of the product (Limited 
Lifetime Warranty) if the warranty card is filled out by the dealer and/or end user and returned to AMX so that AMX receives it 
within thirty (30) days of the installation of equipment but no later than six (6) months from original AMX sales invoice date. The 
life of the product extends until five (5) years after AMX ceases manufacturing the product model. The Limited Lifetime Warranty 
applies to products in their original installation only. If a product is moved to a different installation, the Limited Lifetime Warranty 
will no longer apply, and the product warranty will instead be the three (3) year Limited Warranty.

All products returned to AMX require a Return Material Authorization (RMA) number. The RMA number is obtained from the AMX 
RMA Department. The RMA number must be clearly marked on the outside of each box. The RMA is valid for a 30-day period. After 
the 30-day period the RMA will be cancelled. Any shipments received not consistent with the RMA, or after the RMA is cancelled, will 
be refused. AMX is not responsible for products returned without a valid RMA number.

AMX is not liable for any damages caused by its products or for the failure of its products to perform. This includes any lost profits, lost 
savings, incidental damages, or consequential damages. AMX is not liable for any claim made by a third party or by an AMX Autho-
rized Partner for a third party.

This Limited Warranty does not apply to (a) any AMX product that has been modified, altered or repaired by an unauthorized agent or 
improperly transported, stored, installed, used, or maintained; (b) damage caused by acts of nature, including flood, erosion, or earth-
quake; (c) damage caused by a sustained low or high voltage situation or by a low or high voltage disturbance, including brownouts, 
sags, spikes, or power outages; or (d) damage caused by war, vandalism, theft, depletion, or obsolescence.

This limitation of liability applies whether damages are sought, or a claim is made, under this warranty or as a tort claim (including 
negligence and strict product liability), a contract claim, or any other claim. This limitation of liability cannot be waived or amended by 
any person. This limitation of liability will be effective even if AMX or an authorized representative of AMX has been advised of the 
possibility of any such damages. This limitation of liability, however, will not apply to claims for personal injury.

Some states do not allow a limitation of how long an implied warranty last. Some states do not allow the limitation or exclusion of inci-
dental or consequential damages for consumer products. In such states, the limitation or exclusion of the Limited Warranty may not 
apply. This Limited Warranty gives the owner specific legal rights. The owner may also have other rights that vary from state to state. 
The owner is advised to consult applicable state laws for full determination of rights.

EXCEPT AS EXPRESSLY SET FORTH IN THIS WARRANTY, AMX MAKES NO OTHER WARRANTIES, EXPRESSED OR 
IMPLIED, INCLUDING ANY IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. AMX 
EXPRESSLY DISCLAIMS ALL WARRANTIES NOT STATED IN THIS LIMITED WARRANTY. ANY IMPLIED WARRANTIES THAT 
MAY BE IMPOSED BY LAW ARE LIMITED TO THE TERMS OF THIS LIMITED WARRANTY. EXCEPT AS OTHERWISE LIMITED 
BY APPLICABLE LAW, AMX RESERVES THE RIGHT TO MODIFY OR DISCONTINUE DESIGNS, SPECIFICATIONS, WARRAN-
TIES, PRICES, AND POLICIES WITHOUT NOTICE.

 

Summary of Contents for NXA-PDU-1508-08

Page 1: ...Operation Reference Guide Control System Accessories NXA PDU 1508 08 Power Distribution Unit 240V 10A Last Revised 6 03 2011 NXA PDU 1508 08 Power Distribution Unit 240V 10A Operation Reference Guide ...

Page 2: ...rked on the outside of each box The RMA is valid for a 30 day period After the 30 day period the RMA will be cancelled Any shipments received not consistent with the RMA or after the RMA is cancelled will be refused AMX is not responsible for products returned without a valid RMA number AMX is not liable for any damages caused by its products or for the failure of its products to perform This incl...

Page 3: ... MASTER Connector 6 TEMP Connector 6 Preparing Captive Wires 7 AxLink Data and Power Connections 7 AxLink Wiring Guidelines 7 CONFIG DIP Switch 8 Setting the Device Address of the PDU 8 Power Outlets 1 8 8 Power Inlet 9 Powering On the NXA PDU 1508 8 9 NetLinx Programming 11 Device IDs 11 Supported SEND_COMMANDs 11 PERSIST 11 PERSIST 11 PHASEANGLE 11 RESET 11 SERIAL 11 TRIGGER 12 TRIGGER 12 VER 12...

Page 4: ...ii NXA PDU 1508 8 Power Distribution Unit 240V 10A Table of Contents ...

Page 5: ...s Power Specifications Powered via 240VAC 50 60Hz mains power on an IEC 320 C 14 connector Required voltage 240VAC 50 60Hz Total Combined Current including AxLink 10A Idle current draw 240VAC 50 60HZ 0 5W max Front Panel Components POWER LEDs 1 8 Eight green LEDs illuminate to indicate that the associated Power Outlet 1 8 is in use AXLINK LEDs Two green LEDs illuminate to indicate when the associa...

Page 6: ...Link devices AxLink power is switched in two banks of four outputs each BANK 1 contains AxLink connectors 1 4 BANK 2 contains AxLink connectors 5 8 The PDU provides 6 5A total across all AxLink outputs MASTER connector 3 5mm Phoenix 4 pin AxLink connector provides connectivity to the NetLinx Master always on TEMP RTS input 3 5mm Phoenix 2 pin connector provides connection to a Remote Temperature S...

Page 7: ...ding Be sure that the supply circuit to the rack assembly is not overloaded Grounding Rack mounted equipment should be properly grounded Particular attention should be given to supply connections other than direct connections to the mains The NXA PDU 1508 8 can be mounted in a standard 19 inch equipment rack 1 Attach the brackets to the PDU using the screws provided in the Bracket Mounting Kit FIG...

Page 8: ...NXA PDU 1508 8 4 NXA PDU 1508 8 Power Distribution Unit 240V 10A ...

Page 9: ...a 0 5 second toggle on the AxLink power line Rear Panel Components The rear panel components of the NXA PDU 1508 8 are described below FIG 5 FIG 4 NXA PDU 1508 8 Front Panel Components RESET pushbutton AxLink STATUS LED AxLink BANK 1 POWER Output 1 8 Status LEDs Status LED AxLink BANK 2 Status LED See the Specifications table for descriptions of the LEDs on the front panel FIG 5 NXA PDU 1508 8 Rea...

Page 10: ... TEMP Connector The PDU measures temperature with an accuracy of 1 degree C via a remote temperature probe Temperature data is kept in non volatile storage to retain across reboot The 3 5mm Phoenix 2 pin connector labelled TEMP allows you to connect a Remote Temperature Sensor RTS as an optional accessory FIG 8 The PDU comes with one ENV VST TSF Flush Mount Indoor Temperature Sensor FG2050 21 Conn...

Page 11: ... allowable between the PDU and connected AxLink devices 1 Total current consumption of all connected AxLink devices x Resistance Foot x 2 voltage drop per foot see table below for Resistance Foot values 2 Power supply voltage 12 VDC surplus voltage dissipation for cable run 3 surplus voltage dissipation for cable run voltage drop per foot Maximum distance in feet The following table lists the resi...

Page 12: ...w The device number is set by the total value of DIP switch positions that are in the ON position Note that the ON position is indicated on the DIP Switch If you later change the device number remove and reconnect the power connector to enter the new device number into memory Power Outlets 1 8 The eight 100 240VAC 50 60 Hz IEC C 13 10A AC Power Outlet Connectors provide AC power to connected devic...

Page 13: ...s ON By default Persistence for all outlets is set to ON Persistence can be turned off via the PERSIST SEND_COMMAND see page 11 For subsequent power ups from a power off state or on system reset the PDU will restore the last recorded state of any outlet in a sequenced fashion starting from outlet 1 in numerical order with a delay of 0 5 second between energizing any two outlets assuming the defaul...

Page 14: ...Installation 10 NXA PDU 1508 8 Power Distribution Unit 240V 10A ...

Page 15: ...f the persistent data setting an outlet to PERSIST ON should only be used when absolutely necessary and never for very frequent toggling operations PERSIST Queries the PERSIST state of all outlets Returns a comma delimited list in the form PERSIST 1 value 2 value 3 value 4 value 5 value 6 value 7 value 8 value 9 value 10 value value will be 1 for ON or 0 for OFF e g PERSIST 1 1 2 0 3 0 4 0 5 0 6 0...

Page 16: ... specified value in tenths of Watts Note A Trigger is a current level which will cause a power sense channel to activate if the current exceeds the value TRIGGER Syntax TRIGGER outlet Responds with TRIGGER outlet Power Sense Trigger to report the trigger value in use on the outlet VER Syntax VER Responds with Version string example Vx xx ZAP Syntax ZAP Restores all settings on the PDU to factory d...

Page 17: ... max value of the level is 65535 if that is exceeded the level will roll over to 0 Overcurrent Reporting The PDU reports alerts of overcurrent via the following AxLink string OVERCURRENT Outlet Current 16 bit Level Dev 1 Dev 2 Dev 3 Dev 4 Dev 5 Dev 6 Dev 7 Dev 8 1 Power Power Power Power Power Power Power Power 2 Current Current Current Current Current Current Current Current 3 Power Factor Power ...

Page 18: ...NetLinx Programming 14 NXA PDU 1508 8 Power Distribution Unit 240V 10A ...

Page 19: ...NetLinx Programming 15 NXA PDU 1508 8 Power Distribution Unit 240V 10A ...

Page 20: ...ation knowledge In the ever changing AV industry continual education is key to success AMX University is dedicated to ensuring that you have the opportunity to gather the information and experience you need to deliver strong AMX solutions Plus AMX courses also help you earn CEDIA NSCA InfoComm and AMX continuing education units CEUs Visit AMX University online for 24 7 365 access to Schedules and ...