background image

Key Features

Linear Filtering Technology (LiFT)

For improving picture and sound quality noth-

ing filters AC noise better. LiFT evenly elimi-

nates  noise  across  the  entire  bandwidth,

ensuring  peak  audio  and  video  performance

by reducing harmonic distortion and improv-

ing  the  signal-to-noise  ratio.  With  LiFT,  you

are assured consistent performance and the

highest  resolution  from  any  audio  or  video

playback system.

LiFT Technology EMI/RFI Noise Filtration :

Your audio/video components are constantly

being bombarded by electromagnetic interfer-

ence (EMI) and radio frequency interference

(RFI)  through  their  AC  power  source.  This

contaminated  power  can  affect  audio/video

equipment  and  will  degrade  the  overall  per-

formance  of  your  entire  system.  Common

symptoms  of  contaminated  power  include

loss of picture detail, dull colors, pops, hiss-

es, hums and visual artifacts.

Automatic Over & Under Voltage Protection

(AVM):

Panamax's patent pending power monitoring

circuitry constantly monitors the AC line volt-

age  for  unsafe  voltage  conditions  such  as

momentary  spikes  or  prolonged  over-volt-

ages and under-voltages (brownouts). These

unsafe  conditions  pose  a  very  dangerous

threat  to  all  electronic  equipment  within  the

home.  If  the  M5300-PM  senses  an  unsafe

power condition, it will automatically discon-

nect your equipment from the power to pro-

tect  equipment  from  damage.Once  the  volt-

age returns to a safe level, the M5300-PM will

automatically reconnect the power.

•  When  subjected  to  a  6,000V  (open  circuit

voltage) / 500A (short circuit current) surge,

the  M5300-PM  limits  its  voltage  output  to

less than 330V peak, UL's best rating. 

•  If the magnitude of the surge is greater than

the capacity of the surge protection compo-

nents, the M5300-PM's Protect or Disconnect

Circuitry  will  disconnect  your  equipment  in

order to protect it. The M5300-PM will need

to be repaired or replaced by Panamax if this

occurs within the product’s 3 year warranty.

5 Isolated Outlet Banks

The M5300-PM is designed to provide noise

isolation between the outlet banks so that any

noise  created  by  A/V  components  plugged

into  the  M5300-PM  cannot  contaminate  the

power  going  to  equipment  plugged  into  the

other outlet banks of the M5300-PM.

Sequential Startup/Shutdown:

Complex  audio/video  systems  may  be  sus-

ceptible to voltage transients generated inter-

nally at start-up/shutdown if all of the equip-

ment is powered on or off at the same time.

This can cause speaker “thumps” which are

not  only  annoying  but  can  also  damage  the

speakers and/or trip product circuit breakers.

The M5300-PM is designed to eliminate these

transients by providing a “start-up” delay for

the  High-Current  outlets  and  a  “shutdown”

delay  for  the  Switched  Outlet  Banks.  This

minimizes in-rush current issues by allowing

the  components  plugged  into  the  Switched

Outlet Banks to power-up and stabilize before

any amplifiers and powered sub-woofers are

turned on. This sequence is reversed during

shutdown. The amplifiers and powered sub-

woofers turn off, their power supplies drain,

and  then  the  equipment  plugged  into  the

Switched Outlet Banks are turned off.

USB Charger:

The  M5300-PM  features  a  front  panel  con-

venience  charger  for  mp3  players,  cell

phones,  video  game  controllers,  and  other

small  electronics.  NOTE:  Some  devices  may

not be compatible with this USB charger.

Gaming LAN Port:

The  M5300-PM  features  an  easy-to-access

LAN port pass-thru from the rear panel to the

front panel. Perfect for online gaming.

Gaming Outlet:

The M5300-PM features a convenience outlet

located on the front panel.  Perfect for gaming

systems and other electronics.

Voltage  Sense  Trigger: 

The  MAX5300-PM

voltage  sense  trigger  input  uses  a  standard

3.5mm (1/8") mini-mono plug. 

This  feature  provides  an  ON/OFF  trigger  for

the M5300-PM using a Direct Current voltage

signal. Many components such as pre-ampli-

fiers and receivers have a DC trigger built in,

and  will  transmit  a  constant  power  signal

when turned on and in use. The presence of

this  power  signal  will  turn  on  the  M5300-

PM's switched outlets. When the source com-

ponent is turned off, the voltage trigger signal

is also turned off and the M5300-PM's shut-

down sequence is initiated. An AC Adapter of

the  appropriate  voltage  plugged  into  a

switched outlet may also be used if a DC trig-

ger is not built in. 

Cable/Satellite/Antenna TV signal 

protection

Coaxial  protection  circuits  achieve  optimum

signal quality from our new coaxial protectors

that have the smallest signal loss on the mar-

ket - less than 0.5 db of attenuation from 0

MHz  to  2.2  GHz.  Our  upgraded  coaxial  pro-

tection has been specifically designed to vir-

tually  eliminate  signal  loss.  The  clamping

level  of  75V  will  meet  the  demands  of  both

cable  and  satellite  voltage  while  minimizing

exposure to damaging spikes and surges.

Telephone Line Protection:

Digital  video  recorders  and  satellite  TV

receivers require a telephone line connection

for TV show scheduling and/or Pay-Per-View

services. The M5300-PM provides surge pro-

tection for this utilizing one pair of RJ-11 tele-

phone jacks is provided for this. The circuitry

utilizes  auto-resetting  PTCRs  and  solidstate

SIDACtors  for  reliability  and  unsurpassed

protection. The clamping level of the M5300-

PM's  telephone  protector  is  260  volts.  This

will  allow  typical  ring  voltage  (90-130VAC)

and 

operating 

battery 

voltage 

(-48DC) to pass through the circuit and still

protect  the  modem  in  your  satellite  receiver

from damage.

LAN Protection:

Protection circuits for 10/100 baseT Ethernet

lines.  Incoming  LAN  line  MUST  be  plugged

into  the  LINE  jack.  Patch  cord  to  the  equip-

ment MUST be plugged into the EQUIP jacks.

1  LAN  jack  goes  to  the  front  panel  gaming

port. 8 wire protection, 52V clamping.

BANK 1        BANK 2        BANK 3        BANK 4        BANK 5      

LINEAR        LINEAR         LINEAR         LINEAR          HIGH          WIRING

 FILTER        FILTER          FILTER          FILTER       CURRENT        OK      

M5300-PM

 METER LIGHTS

VOLTS

AMPS

Model: 

M5300-PM

INS00816-E   Rev. C       9/09

1

CAUTION

 – Do not install this device if there is not at least 10 meters (30 feet) or more of wire between the electrical outlet and electrical service panel.

Summary of Contents for M5300-PM

Page 1: ...nce is reversed during shutdown The amplifiers and powered sub woofers turn off their power supplies drain and then the equipment plugged into the Switched Outlet Banks are turned off USB Charger The...

Page 2: ...ment M5300 PM Back Panel Connection Features M5300 PM Front Panel Features Bank 1 and 2 Indicator Light Normally ON is lit when there is power present on Bank 1 and 2 receptacles Ground Lug Provides...

Page 3: ...24V DC Trigger Output Pass through no delay Positive Tip Negative Ring LAN Circuits Clamping Level 52V Jacks RJ 45 Wires Protected 8 Wires USB Circuit Jacks USB A Power Delivery 500 mA 5VDC Telephone...

Page 4: ...m of your system will be required as part of the claim kit Be sure to note its con figuration before disconnecting your equipment 4 DETERMINATION OF FAILURE Panamax will evaluate the protector for sur...

Page 5: ...alquier amplificador o sub woofer activo Esta secuencia se invierte durante el apagado Los amplificadores y los sub woofers activos se apagan se vac a la energ a de sus fuentes de poder y a contin uac...

Page 6: ...e debe conectarse al sistema de puesta a tierra del edificio y tan cerca de la acometida como sea posible Indicador de voltaje peligroso Ubicado en el volt metro el indicador de voltaje peli groso nor...

Page 7: ...nal Corriente necesaria 4 6 mA 3V 58 mA 24V Salida de disparador de corriente directa Atraviesa sin demora Positivo Punta Negativo Timbre Circuitos de red local Nivel de fijaci n 52 V Conectores RJ 45...

Page 8: ...ue deber rellenar y devolvernos en un plazo de 30 d as Dentro de la doc umentaci n de reclamaci n se le pedir que incluya una diagrama de conexi n de su sistema No olvide anotar esta configuraci n ant...

Page 9: ...ns des basses sont mis hors tension leur alimentation se d charge et finalement les quipements qui sont branch s aux blocs prises commut es sont mis hors tension Chargeur USB le MAX 5300 PM est quip d...

Page 10: ...it tre branch sur l installation de mise la terre du b timent aussi pr s de l entr e du c ble que possible Indicateur de tension dan gereuse Situ dans le voltm tre l indi cateur de tension dangereuse...

Page 11: ...eur c c Prises mini jack 3 5mm 1 8 po mono Tension et polarit 3 24V c c bidirectionnel Caract ristiques du courant 4 6 mA 3V 58 mA 24V Sortie du d clencheur c c Transmission directe sans d lai Positif...

Page 12: ...ter que l envoi Panamax s effectue vos frais Si vous avez not une demande concernant des quipements connect s endommag s lors de la demande d autorisation de retour d article Panamax vous enverra un d...

Reviews: