background image

Panamax

1690 Corporate Circle

Petaluma, CA 94954

Phone - 707-283-5900 or 800-472-5555

Fax - 707-283-5901

Web - www.panamax.com

Customer Relations 

7:30 AM – 4:30 PM, M-F

Email - [email protected]

One telephone patch cord

48 inches

One LAN cable (CAT-5)

48 inches

Product warranty (see page 4)

One coaxial cable, 36 inches

AC Power

Line Voltage:...................................................................120V, 60Hz

Total Current Capacity:..............................................................15 A

Protection Modes:.......................................................L-N, L-G, N-G

Initial Clamping Level:..............................................................200V

Energy Dissipation:........................................................2125 Joules

Peak Impulse Current:.................................................72,000 Amps

Catastrophic Surge Circuit:..........................................................Yes

Thermal Fusing:..........................................................................Yes

Over-voltage shutoff:.............................................142 VAC ± 8 VAC

Under-voltage shutoff:.............................................90 VAC ± 2 VAC

EMI/RFI Noise Filtration

Banks 1, 2, 3, 4..........................................80 db, 100 KHz - 2 MHz

Bank 5 High Current Outlets:.....................60 db, 100 KHz - 2 MHz

DC Trigger Input

Jacks:................................................3.5mm (1/8”) mono mini-plug

Voltage and Polarity:.................................3 - 24V DC, bidirectional

Current Requirement:............................4.6 mA @3V, 58 mA @24V

DC Trigger Output

Pass through.......................................................................no delay

Positive = Tip, Negative = Ring

LAN Circuits

Clamping Level:..........................................................................52V

Jacks:......................................................................................RJ-45

Wires Protected:...................................................................8-Wires

USB Circuit

Jacks......................................................................................USB-A

Power Delivery...................................................... 500 mA @ 5VDC

Telephone Circuit

Fuseless/Auto-resetting:.............................................................Yes

Clamping Level:........................................................................260V

Capacitance:...............................................................30pf (approx.)

Suppression Modes:.....................................Metallic & Longitudinal

Jacks:......................................................................................RJ-11

Wires Protected:..................................................2-Wire, Pins 4 & 5

Cable and Satellite Circuits

HD 1080 i/p Ready .....................................................................Yes

Bi-directional...............................................................................Yes

Shielded......................................................................................Yes

Clamping Level...........................................................................75V

Frequency Range.....................................................0MHz - 2.2 GHz

Insertion Loss.....................................................................< 0.5 dB

Connections................................................Female “F”, Gold Plated

M5300-PM Specifications

Contacting Panamax

Contents

© 2009  Panamax, Inc.  Panamax, MAX and the Panamax logo are registered US trademarks of Panamax.  Protect or Disconnect and SignalPerfect are trademarks of Panamax, Inc. 

SIDACtor is a registered US trademark of Teccor Electronics, Inc. Foreign Language Version produced by International Contact, Inc.

Specifications are subject to changes due to product upgrades and improvements.

3

One Rack Mount Kit

Voltage Protection Rating (UL1449 3rd Edition, 3,000A):........ 500V

Summary of Contents for M5300-PM

Page 1: ...nce is reversed during shutdown The amplifiers and powered sub woofers turn off their power supplies drain and then the equipment plugged into the Switched Outlet Banks are turned off USB Charger The...

Page 2: ...ment M5300 PM Back Panel Connection Features M5300 PM Front Panel Features Bank 1 and 2 Indicator Light Normally ON is lit when there is power present on Bank 1 and 2 receptacles Ground Lug Provides...

Page 3: ...24V DC Trigger Output Pass through no delay Positive Tip Negative Ring LAN Circuits Clamping Level 52V Jacks RJ 45 Wires Protected 8 Wires USB Circuit Jacks USB A Power Delivery 500 mA 5VDC Telephone...

Page 4: ...m of your system will be required as part of the claim kit Be sure to note its con figuration before disconnecting your equipment 4 DETERMINATION OF FAILURE Panamax will evaluate the protector for sur...

Page 5: ...alquier amplificador o sub woofer activo Esta secuencia se invierte durante el apagado Los amplificadores y los sub woofers activos se apagan se vac a la energ a de sus fuentes de poder y a contin uac...

Page 6: ...e debe conectarse al sistema de puesta a tierra del edificio y tan cerca de la acometida como sea posible Indicador de voltaje peligroso Ubicado en el volt metro el indicador de voltaje peli groso nor...

Page 7: ...nal Corriente necesaria 4 6 mA 3V 58 mA 24V Salida de disparador de corriente directa Atraviesa sin demora Positivo Punta Negativo Timbre Circuitos de red local Nivel de fijaci n 52 V Conectores RJ 45...

Page 8: ...ue deber rellenar y devolvernos en un plazo de 30 d as Dentro de la doc umentaci n de reclamaci n se le pedir que incluya una diagrama de conexi n de su sistema No olvide anotar esta configuraci n ant...

Page 9: ...ns des basses sont mis hors tension leur alimentation se d charge et finalement les quipements qui sont branch s aux blocs prises commut es sont mis hors tension Chargeur USB le MAX 5300 PM est quip d...

Page 10: ...it tre branch sur l installation de mise la terre du b timent aussi pr s de l entr e du c ble que possible Indicateur de tension dan gereuse Situ dans le voltm tre l indi cateur de tension dangereuse...

Page 11: ...eur c c Prises mini jack 3 5mm 1 8 po mono Tension et polarit 3 24V c c bidirectionnel Caract ristiques du courant 4 6 mA 3V 58 mA 24V Sortie du d clencheur c c Transmission directe sans d lai Positif...

Page 12: ...ter que l envoi Panamax s effectue vos frais Si vous avez not une demande concernant des quipements connect s endommag s lors de la demande d autorisation de retour d article Panamax vous enverra un d...

Reviews: