background image

®

TM

®

Power Protection Series 

PD11VBC

Owner’s Manual

1532 Enterprise Pkwy, Twinsburg OH 44087  •  (800) 321-6699  •  (330) 425-3388  •  www.etasys.com

6MAN-037

A Creative Light And Sound Company

1532 Enterprise Pkwy, Twinsburg OH 44087  •  (800) 321-6699  •  (330) 425-3388  •  www.etasys.com

A Creative Light And Sound Company

TM

Summary of Contents for PD11VBC

Page 1: ...nual 1532 Enterprise Pkwy Twinsburg OH 44087 800 321 6699 330 425 3388 www etasys com 6MAN 037 A Creative Light And Sound Company 1532 Enterprise Pkwy Twinsburg OH 44087 800 321 6699 330 425 3388 www etasys com A Creative Light And Sound Company TM ...

Page 2: ...ation of sophisticated noise filtration circuit ry and the world s finest surge protec tion has resulted in an Audio Video power center that meets the power quality needs for each piece of equip ment in your entertainment system The styling of the PD11VBC comple ments even the most sophisticated Audio Video showcase 2003 ETA Systems SIDACtor is a registered US trademark of Teccor Electronics inc T...

Page 3: ...t power spikes A surge is similar to a spike but will last for longer periods of time 15 milliseconds to 2 5 seconds and reach up to 500 volts Utility grid switching and motors turning on or off cause most power surges Both surges and spikes are damaging to sensitive solid state components present in Audio Video equipment What is the difference between an Overvoltage and Undervoltage An overvoltag...

Page 4: ...ality of your listening and or viewing experience Our goal is to Provide clean pure power Protect your investment Enhance the pleasure you get from you re A V system Thank you for choosing ETA for your power quality needs Please finish reading the instructions install your PD11VBC and enjoy the full potential of your entertainment sys tem 11 TECHNICAL SPECIFICATIONS Clamping Level 260V Capacitance...

Page 5: ...hreshold 137VAC or falls below the undervoltage threshold 95VAC the PD11VBC will perform the following tasks until line voltage returns to a safe level 1 Disconnects power to all connected equipment 2 Unsafe Voltage LED is activated and will blink once per second during the unsafe voltage condition The PD11VBC requires line voltage to return to within the safe operating range for 10 seconds before...

Page 6: ... DETAILS Coaxial Line Protection All coaxial cable sheaths from outdoors must be grounded to the building grounding electrode system where they enter the building per applicable NEC CEC code A driven ground rod is not adequate The PD11VBC provides application specific protection for your satellite and cable TV equipment Two lines of protection are provided for each type The satellite connections a...

Page 7: ...urn off before Outlet Bank 2 if they re not set to Always On With a delay the connected equipment will not power up simultaneously thus preventing loudspeaker noises such as thump ing See the Sequential Startup Shutdown section for more information Voltage Sense Trigger This feature provides an ON OFF trigger for the PD11VBC using a DC remote control signal Many components such as pre amplifiers a...

Page 8: ...stabilize before any amplifiers and powered sub woofers are turned on This sequence is reversed dur ing shutdown The amplifiers and powered sub woofers turn off their power supplies drain then the equipment plugged into Outlet Bank 2 is turned off Information on setting the delay times is included in the Outlet Bank 2 and High Current Outlet Bank sections that follow Filtered Outlet Banks 1 2 Eigh...

Reviews: