background image

10

3

PERSONAL VIDEO RECORDER

SATELLITE RECEIVER

MINI DISC PLAYER

AMPLIFIER

AUDIO VIDEO RECEIVER

DVD PLAYER

LASER DISC PLAYER

SUBWOOFER

TV

DOWNLINE TV

IN ANOTHER 

ROOM

PHONE 
 JACK

CD PLAYER

  OUTDOOR 
FM ANTENNA

    DUAL LNB 
SATELLITE DISH

AC LINE

COAX LINE

TELEPHONE LINE

12VDC LINE

 PROPERLY 
GROUNDED 
 AC OUTLET

CONNECTION DIAGRAM

FEATURE DETAILS

AC Surge Protection

When the PD11VBC  is subjected to a high voltage surge, its voltage output is limited to a safe level and the high levels 
of surge current are diverted away from the connected equipment.

• When subjected to a 6,000V (open circuit voltage) / 500A (short circuit current) surge, the PD11VBC limits 

its voltage output to less than 330V peak, UL’s  lowest rating.  The PD11VBC will withstand, without 
damage, multiple 12,000A surges, far exceeding the UL maximum requirement of only  3,000 Ampere surges.

• If the magnitude of the surge is greater than the capacity of the surge protection components, the PD11VBC’s 

circuitry will disconnect your equipment in order to protect it.  The PD11VBC will need to be repaired or replaced 
by ETA if this occurs.

The PD11VBC constantly monitors the AC line voltage for unsafe voltage conditions such as prolonged overvoltages 
and undervoltages (brownouts).  These unsafe conditions pose a very dangerous threat to all electronic equipment within 
the home.  If the PD11VBC senses an unsafe power condition, it will automatically 

disconnect 

your equipment from 

the power to protect equipment from damage.  Once the voltage returns to a safe level, the PD11VBC will automatically 

reconnect 

the power.

If the line voltage exceeds the overvoltage threshold (137VAC) or falls below the undervoltage threshold (95VAC), the 
PD11VBC will perform the following tasks until line voltage returns to a safe level:

1. Disconnects power to all connected equipment.
2. Unsafe Voltage LED is activated and will blink once per second during the unsafe voltage condition.

The PD11VBC requires line voltage to return to within the safe operating range for 10 seconds before returning to normal operat-
ing mode.  This is referred to as “Over/Undervoltage Recovery”.  The safe operating range is considered 5V above the under-
voltage threshold (~100V) and 5V below the overvoltage threshold (~132V).  Once this safe operating range is reached, 
the PD11VBC will perform the following functions:

1. Unsafe Voltage LED will blink 4 times per second for Over/Undervoltage Recovery.
2. Power is restored to all connected equipment after the 10-second delay.  The normal start-up sequence as 

determined by the “High-Current Outlets Turn-On Switch” and “Outlet Bank 2 Turn-Off Switch” will be followed. 

The PD11VBC provides protection against common problems on the AC power lines.  This includes spikes/surges and
sustained overvoltages or undervoltages.  The circuitry is designed to protect against spikes/surges and special circuitry is
for sustained over/under voltage protection.

1.

Voltage reaches an unsafe high

level and the PD11VBC 

disconnects.

2.

Voltage reaches a safe level and

the PD11VBC automatically 

reconnects.

3.

Voltage reaches an unsafe low level,

the PD11VBC 

disconnects.

4.

Voltage reaches a safe level and

the PD11VBC automatically 

reconnects.

1.

Voltage reaches an unsafe level.

2.

If surge is greater than 

PD11VBC capacity, 
it 

disconnects.

1532 Enterprise Pkwy, Twinsburg OH 44087  •  (800) 321-6699  •  (330) 425-3388  •  www.etasys.com

1532 Enterprise Pkwy, Twinsburg OH 44087  •  (800) 321-6699  •  (330) 425-3388  •  www.etasys.com

 

Summary of Contents for PD11VBC

Page 1: ...nual 1532 Enterprise Pkwy Twinsburg OH 44087 800 321 6699 330 425 3388 www etasys com 6MAN 037 A Creative Light And Sound Company 1532 Enterprise Pkwy Twinsburg OH 44087 800 321 6699 330 425 3388 www etasys com A Creative Light And Sound Company TM ...

Page 2: ...ation of sophisticated noise filtration circuit ry and the world s finest surge protec tion has resulted in an Audio Video power center that meets the power quality needs for each piece of equip ment in your entertainment system The styling of the PD11VBC comple ments even the most sophisticated Audio Video showcase 2003 ETA Systems SIDACtor is a registered US trademark of Teccor Electronics inc T...

Page 3: ...t power spikes A surge is similar to a spike but will last for longer periods of time 15 milliseconds to 2 5 seconds and reach up to 500 volts Utility grid switching and motors turning on or off cause most power surges Both surges and spikes are damaging to sensitive solid state components present in Audio Video equipment What is the difference between an Overvoltage and Undervoltage An overvoltag...

Page 4: ...ality of your listening and or viewing experience Our goal is to Provide clean pure power Protect your investment Enhance the pleasure you get from you re A V system Thank you for choosing ETA for your power quality needs Please finish reading the instructions install your PD11VBC and enjoy the full potential of your entertainment sys tem 11 TECHNICAL SPECIFICATIONS Clamping Level 260V Capacitance...

Page 5: ...hreshold 137VAC or falls below the undervoltage threshold 95VAC the PD11VBC will perform the following tasks until line voltage returns to a safe level 1 Disconnects power to all connected equipment 2 Unsafe Voltage LED is activated and will blink once per second during the unsafe voltage condition The PD11VBC requires line voltage to return to within the safe operating range for 10 seconds before...

Page 6: ... DETAILS Coaxial Line Protection All coaxial cable sheaths from outdoors must be grounded to the building grounding electrode system where they enter the building per applicable NEC CEC code A driven ground rod is not adequate The PD11VBC provides application specific protection for your satellite and cable TV equipment Two lines of protection are provided for each type The satellite connections a...

Page 7: ...urn off before Outlet Bank 2 if they re not set to Always On With a delay the connected equipment will not power up simultaneously thus preventing loudspeaker noises such as thump ing See the Sequential Startup Shutdown section for more information Voltage Sense Trigger This feature provides an ON OFF trigger for the PD11VBC using a DC remote control signal Many components such as pre amplifiers a...

Page 8: ...stabilize before any amplifiers and powered sub woofers are turned on This sequence is reversed dur ing shutdown The amplifiers and powered sub woofers turn off their power supplies drain then the equipment plugged into Outlet Bank 2 is turned off Information on setting the delay times is included in the Outlet Bank 2 and High Current Outlet Bank sections that follow Filtered Outlet Banks 1 2 Eigh...