Configuring Communication
34
5" Modero Widescreen Touch Panel
8.
Obtain the System Number and Master IP Address from NetLinx Studio. This information must be
specific for the system used with the configured Modero panel.
9.
Press the grey Front Setup Access button for
3 seconds
to open the Setup page.
10.
Press the
Protected Setup
button (located on the lower-left of the panel page) to open the Protected
Setup page.
11.
Press the
System Connection
button (located on the Protected Setup page) to open the System
Connection page (FIG. 32) and begin configuring the communication settings on the panel to match
those of the target Master.
FIG. 31
Protected Setup page
Before continuing, open NetLinx Studio. This program assists in developing a System
Number, Master IP/URL, and Master Port number. Refer to your NetLinx Master’s
instruction manuals for more information.
FIG. 32
System Connection page
MAC Address
NetLinx Master’s
connection
Modero
connection
information
from panel is
factory set to a
unique address
information
There are 2 possible Master Connection Types available:
USB
or
Ethernet
.
A USB connection type is a
direct connection
from the panel’s mini-USB port to a
corresponding USB port on the PC (acting as a Virtual Master).
An Ethernet connection type involves indirect communication from the panel to a
Master via an Ethernet connection to the network.
Summary of Contents for Modero NXD-CV5
Page 12: ...Introduction 6 5 Modero Widescreen Touch Panel...
Page 18: ...CV5 Touch Panel Accessories 12 5 Modero Widescreen Touch Panel...
Page 58: ...Configuring Communication 52 5 Modero Widescreen Touch Panel...
Page 98: ...Firmware Pages and Descriptions 92 5 Modero Widescreen Touch Panel...
Page 158: ...Appendix A 152 5 Modero Widescreen Touch Panel...
Page 159: ...Appendix A 153 5 Modero Widescreen Touch Panel...
Page 160: ...Appendix A 154 5 Modero Widescreen Touch Panel...
Page 161: ...Appendix A 155 5 Modero Widescreen Touch Panels...