![AMX MAX-CSD 10 Operation And Reference Manual Download Page 61](http://html1.mh-extra.com/html/amx/max-csd-10/max-csd-10_operation-and-reference-manual_2938532061.webp)
Configuring Communication
55
MAX-CSE/MAX-CSD10 Operation/Reference Guide
You must use a value which is not currently being used by another device currently
communicating with the target Master.
The Default value is
32001
.
Within Studio, connect to the target Master, click on the
Online Tree
tab to review what
device values are already being used (FIG. 35).
5.
Within the
Master IP/URL
field, enter the IP Address or URL used by the target Master. This is the
same IP Address used by NetLinx Studio to communicate with the Master.
6.
Unless otherwise necessary, do not alter the default value entered within the Master Port field. This
field allows you to enter the port number used by the NetLinx Master.
The Default value is
1319
.
7.
Click the
Apply
button to complete the configuration process and save the parameters to the MAX
unit.
8.
Confirm that the target Master is not configured for require encryption and communicate via a
secured ICSP connection. It is not necessary to remove all security from a target Master to establish
a connection.
Use a second instance of your browser to navigate to the UI pages of the target Master (via the
device’s IP Address).
After successfully logging into the Master, locate the Security section of the left Navigation
frame and click on the
System Level
link to open the System Security Settings page.
Uncheck the
ICSP Connectivity
and
Require Encryption
options (see FIG. 19 on page 33).
This allows an unencrypted device using ICSP to communicate with the target NetLinx
Master.
Click the on-screen
Update
button to save this new configuration to the target Master.
9.
Confirm the MAX unit is properly communicating with the target Master by using NetLinx Studio
to confirm the presence of the new device within the Master’s System listing (FIG. 35).
This listing of devices recognized by the target Master can be found by refreshing the System
listing within the
Online Tree
tab.
Refer to the
Communicating with the Target Master via an IP
section on page 52 for detailed
procedures.
FIG. 35
Studio Online Tree tab showing the communicating MAX unit
Communicating MAX unit
(showing current installed firmware version)
Summary of Contents for MAX-CSD 10
Page 6: ...iv MAX CSE MAX CSD10 Operation Reference Guide Table of Contents...
Page 14: ...MAX CSD10 Video Decoder 8 MAX CSE MAX CSD10 Operation Reference Guide...
Page 24: ...MAX CSE and MAX CSD10 Installation 18 MAX CSE MAX CSD10 Operation Reference Guide...
Page 80: ...Displaying Stream Content 74 MAX CSE MAX CSD10 Operation Reference Guide...
Page 108: ...NetLinx Programming 102 MAX CSE MAX CSD10 Operation Reference Guide...
Page 109: ...Programming 103 MAX CSE MAX CSD10 Operation Reference Guide...