Serial Commands (Cont.)
INP
Activates the indicated source input.
Syntax:
INP<input>
Variable:
input = source input (1-4)
Example:
INP1,$0D
Activates source input 1.
INP?
Queries the current active source input; returns the current source input.
Syntax:
INP?,$0D
Sample Output:
INPUT=1
LAMP?
Queries the lamp status of the display; returns the current lamp status.
Note
: This command cannot be implemented on HDMI Passthru wallplates.
Syntax:
LAMP?,$0D
Sample Output:
"Lamp = xxxx"
where xxxx = number of hours
If the system lamp time cannot be determined:
"Lamp = Unknown"
MMD
Sets mono mode. In mono mode, the left and right inputs are mixed together and presented on both left and
right output channels.
Syntax:
MMD,$0D
MUT
Toggles the audio/video mute.
Note
: This command cannot be implemented on HDMI Passthru wallplates.
Syntax:
MUT,$0D
PBD
Sets the display port baud rate.
Syntax:
PBD<baud>,<parity>,<data>,<stop>
Variables:
baud = baud rates are: 115200, 57600, 38400, 19200, 9600, 4800, 2400, 1200.
parity = N (none), O (odd), E (even).
data = 7 or 8 data bits.
stop = 1 or 2 stop bits.
Example:
PBD115200,N,8,1
Sets the display port's baud rate to 115200 baud, no parity, 8 data bits, 1 stop bit.
Note:
The AVX-400 does not send a response to this command.
PDI
Returns from passthru mode; re-enables interrogation.
Syntax:
PDI,$0D
PEN
Puts the AVX-400 into passthru mode; disables all interrogation.
Syntax:
PEN,$0D