Troubleshooting
62
DGX Transmitters & Receivers Instruction Manual
Error Code Reporting (Power LED is Solid Amber)
Error code reporting is available via a terminal emulation program (e.g., TeraTerm, PuTTY, or
HyperTerminal). If the Power LED illuminates solid amber, we recommend determining the error code
before contacting technical support.
PC Requirements
Windows XP Professional
®
or Windows 2000
®
Terminal emulation program
USB port
To determine the error code (error code reporting):
1.
Connect the module to a PC via the USB port.
2.
Establish a virtual COM port (for requirements and instructions, see page 67).
3.
Open a terminal emulation program (e.g., TeraTerm, PuTTY, or HyperTerminal).
An error code is reported within 5 seconds.
4.
Record the error code and try the recommended course of action in the table below.
If the course of action does not correct the problem, contact technical support (see page 64).
To clear all errors in the error message queue:
1.
Enter the BCS command:
~cle!
Or
Power cycle the module by unplugging the desktop power supply from the power source and
plugging it back in.
Error Codes
If the recommended course of action for the specific error code in the table below does not resolve the
problem, you will need to contact technical support (see page 64).
TX Error Codes
Error Description
Recommended Course of Action
E01
I2C Write failure
Cycle power for the TX.
E02
I2C Read failure
Cycle power for the TX.
E03
I2C Dev Init failure
Cycle power for the TX.
E08
Incompatible Firmware / Hardware failure Use the splash screen to check that the
firmware/hardware versions match the ones
in the upgrade kit. Upgrade accordingly.
RX Error Codes
Error Description
Recommended Course of Action
E01
I2C Write failure
Cycle power for the RX.
E02
I2C Read failure
Cycle power for the RX.
E04
SPI Bus Comm failure
Cycle power for the RX.
E05
EDID Read failure
Cycle power on the display monitor; let the
RX attempt to read the EDID with the
monitor power down.
If unsuccessful, try using an alternate port
on the monitor.
E06
Scaler FPGA NConf failure
Cycle power for the RX at the AC cord.
E08
Incompatible Firmware/Hardware failure
Use the splash screen to check that the
firmware/hardware versions match the ones
in the upgrade kit. Upgrade accordingly.
Summary of Contents for AVB-RX-DGX-SC Fiber-DVI
Page 10: ...Notices 6 DGX Transmitters Receivers Instruction Manual ...
Page 54: ...Adjusting Video with BoardConfig Software 50 DGX Transmitters Receivers Instruction Manual ...
Page 60: ...EDID Programmer 56 DGX Transmitters Receivers Instruction Manual ...
Page 70: ...Troubleshooting 66 DGX Transmitters Receivers Instruction Manual ...
Page 76: ...Appendix B Restoring Default Settings 72 DGX Transmitters Receivers Instruction Manual ...