READ CAREFULLY THE PRODUCT 

INSTALLATION & OPERATION INSTRUCTIONS.   

FAILURE TO FOLLOW THE INSTRUCTIONS AND WARNINGS IN THE 

MANUAL MAY RESULT IN SERIOUS OR FATAL INJURY AND/OR 

PROPERTY DAMAGE, AND WILL VOID THE PRODUCT WARRANTY.  

THIS PRODUCT MUST BE INSTALLED BY A LICENSED 

PROFESSIONAL.  FOLLOW ALL APPLICABLE LOCAL AND STATE 

CODES AND REGULATIONS, IN THE ABSENCE OF SUCH CODES, 

FOLLOW THE CURRENT EDITIONS OF THE NATIONAL PLUMBING 

CODE AND NATIONAL ELECTRIC CODE, AS APPLICABLE.

EXPLOSION HAZARD.

 Failure to follow the 

instructions in the accompanying product manual 

can cause a rupture or explosion; possibly causing serious or fatal injury, 

leaking or flooding and/or property damage.

Use only with potable water system.  Do not operate 

in a setting with freezing temperatures or where the 

temperature can exceed 130°F and do not exceed the maximum working 

pressure specified for this Product in the Manual.  Mount vertically only.

Chlorine & Aggressive Water:

 The water quality 

can significantly influence the life of this Product.  

You should test for corrosive elements, acidity, total solids and other 

relevant contaminants, including chlorine and treat your water appropriately 

to insure satisfactory performance and prevent premature failure.

This Product, like most Products under pressure, 

may over time corrode. weaken and burst or explode, 

causing serious or fatal injury, leaking or flooding and/or property damage.  

To minimize risk, a licensed professional must install and periodically 

inspect and service the Product.  A drip pan connected to an adequate 

drain must be installed if leaking or flooding could cause property damage.  

Do not locate in an area where leakage of the tank or connections could 

cause property damage to the area adjacent to the appliance or to lower 

floors of the structure.

EXPLOSION OR RUPTURE HAZARD 

A relief valve 

must be installed to prevent pressure in excess of 

local code requirement or maximum working pressure designated in the 

Product Manual, whichever is less.  Do not expose Product to freezing 

temperatures or temperatures in excess of 130° F.  Do not adjust the 

pre-charge or re-pressure this Product except for any adjustments 

required at the time of initial installation, especially if Product corroded, 

damaged or with diminished integrity.  Adjustments to pre-charge must 

be done at ambient temperature only.  Failure to properly size the 

Product or follow these instructions may result in excessive strain on the 

system lead to Product failure, serious or fatal personal injury, leakage 

and/or property damage.

This product can expose you to chemicals including 

lead, which is known to the State of California to 

cause cancer and birth defects or other reproductive harm. For more 

information go to www.P65Warnings.ca.gov. 

NOTE:

  Inspect for shipping damage and notify freight carrier or store where purchased immediately if damage is present.  To avoid risk of personal 

injury and property damage, if the product appears to be malfunctioning or shows signs of corrosion, call a licensed professional immediately.  Current 

copies of the Product manual can be viewed at www.amtrol.com.  Use proper safety equipment when installing. 

THIS IS THE SAFETY ALERT SYMBOL. IT IS USED TO ALERT YOU TO POTENTIAL PERSONAL INJURY AND OTHER 

HAZARDS. OBEY ALL SAFETY MESSAGES THAT FOLLOW THIS SYMBOL TO REDUCE THE RISK OF PERSONAL 

INJURY AS WELL AS PROPERTY DAMAGE.

WELL-X-TROL

®

 WELL-X1

® 

WITH GUARIAN CP

®

 CONTROL

INSTALLATION & OPERATION INSTRUCTIONS

Summary of Contents for WELL-X-TROL WELL-X1

Page 1: ...not locate in an area where leakage of the tank or connections could cause property damage to the area adjacent to the appliance or to lower floors of the structure EXPLOSION OR RUPTURE HAZARD A reli...

Page 2: ...with a mechanical pressure switch when installed with three wire 230 vac pumps or any 3 phase pump a standard pump motor starter or a relay must be used A water test must be taken before installation...

Page 3: ...n above ground only Do not install horizontally or directly bury the unit The Well X1 may be installed below grade in a well pit or other suitable enclosure Do not locate in an area where leaking or f...

Page 4: ...valve on the outgoing line This will allow the Well X1 to be tested prior to pressurizing the entire system DO NOT place a shutoff on the incoming supply line NOTE The relief valve is sized for a max...

Page 5: ...conduit connections and wire nuts for an outside application 3 Wiring is similar to a traditional mechanical pressure switch Two leads are connected to line supply while the other supply the pump moto...

Page 6: ...above 10 psig Depressing the s arrow will temporarily override the low water cut off to allow proper priming 5 The factory cut out pump off setting is 60 psig When the pump reaches 60 psig the Well X1...

Page 7: ...K AND SET CUT IN 5 To adjust the cut out depress once and the display will read HI Again press thetor s buttons to raise or lower the setting The same 10 55 psig differential range applies Maximum set...

Page 8: ...oo high 2 Recurring error 1 Adjust air pressure 2 psi below cut in setting 2 See Error Code section for possible causes No pressure pump runs 1 No pump prime jet pumps 2 Failing well pump 3 Incorrect...