PUMP PROTECTION AND DIAGNOSTICS

The Well-X1

®

 continually monitors pressure, cycle time and voltage to protect the well pump. The following error codes 

alert the user to a potential problem, prompting service. When an error occurs, the display will flash a diagnostic code.

WELL-X1 ERROR CODE

POSSIBLE CAUSES AND CONTROL ACTION

E1: Rapid Cycle

Multiple cycles below a safe runtime indicate an incorrect precharge, 

undersized Well-X1 or waterlogged tank. Pump continues to run.

E2: Low Suction

Pump operation below 10 psi indicates a low well level, well piping leak, 

insufficient prime, failing pump or loose wiring. Pump will shut  down and 

attempt to restart every 60 minutes.

E3: Voltage Protection

If line voltage varies outside a safe operating range, low or high, the control will 

run for up to two minutes to ensure water is available, then shut the pump off 

until voltage is restored to a normal range.

TROUBLESHOOTING

PROBLEM

POSSIBLE CAUSE

SOLUTION

Error code flashes

1. Error encountered

1. See Error Code section for possible causes.

No water at fixtures

1. Error encountered

2. No power

3. Water line obstructed

4. Faulty pump

5. Drain or relief valve open

6. Leak in plumbing

1. See Error Code section for possible causes.

2. Check circuit breaker and wiring.

3. Ensure shut-off valves are open, check filtration equipment.

4. Repair or replace as necessary.

5. Ensure valves are closed.

6. Check piping.

Low water pressure

1. Pressure setting too low

2. Water line obstructed

3. Faulty pump

4. Pressure setting out of range

5. Incorrect wiring

1. Adjust pump cut-in and cut-out setting as described in manual.

2. Ensure shut-off valves are open, check any filtration equipment.

3. Check well pump.

4. Reduce pressure settings within pump capacity.

5. Check pump wiring.

Intermittent water interruption

1. Tank precharge too high

2. Recurring error

1. Adjust air pressure 2 psi below cut-in setting.

2. See Error Code section for possible causes.

No pressure (pump runs)

1. No pump prime (jet pumps)

2. Failing well pump

3. Incorrect wiring

1. Prime pump and restart.

2. Repair or replace as necessary.

3. Check pump wiring.

Display will not illuminate

1. Circuit breaker or switch off

2. Faulty or loose wiring

3. Failed control

1. Check breaker and service switch.

2. Check line supply wiring.

3. Replace.

Pump will not turn on 

(Display illuminated)

1. Error encountered

2. Faulty pump

3. Failed control

4. Pressure sensor line blocked

5. Loose or faulty wiring

1. See Error Code section for possible causes.

2. Repair or replace as necessary.

3. Replace.

4. Remove and clean.

5. Check pump wiring.

Pump will not shut off

1. Pressure setting too high

2. Pump water line obstructed

3. Pump problem

4. Failed control

1. Decrease pressure settings until pump and reach cut-out.

2. Ensure no shut-offs are closed between pump and Well-X1

.

3. Inspect pump and sizing if cut-out not reached.

4. Replace.

Sediment or discoloration in water 1. Poor water quality

1. Install proper treatment equipment, drain and flush tank per 

instructions contained in this manual.

Rapid pump cycling

1. Differential too narrow

2. Improper precharge

3. Failed tank

1. Check sizing for intended operating range or spread differential 

to obtain proper pump run time.

2. Adjust air pressure 2 psi below cut-in setting.

3. Replace.

Relief valve discharges

1. Over-pressure condition

2. Faulty relief valve

1. See "Pump will not shut off" above.

2. If pressure is below 100 psi, relief valve should not open. Replace.

Warranty

WX1 Models: Seven (7) Year Limited Warranty (Tank). Two (2) Year Limited Warranty (Control). 

Visit www.amtrol.com for complete warranty details.

© 2019 Worthington Industries Inc. 

Part #: 9013-0006 (01/19)

One or more features of this product are covered by U.S. patents, visit www.amtrol.com/patents for more information.

1400 Division Road, West Warwick, RI  USA 02893

T: 800.426.8765  

www.amtrol.com

Summary of Contents for WELL-X-TROL WELL-X1

Page 1: ...not locate in an area where leakage of the tank or connections could cause property damage to the area adjacent to the appliance or to lower floors of the structure EXPLOSION OR RUPTURE HAZARD A reli...

Page 2: ...with a mechanical pressure switch when installed with three wire 230 vac pumps or any 3 phase pump a standard pump motor starter or a relay must be used A water test must be taken before installation...

Page 3: ...n above ground only Do not install horizontally or directly bury the unit The Well X1 may be installed below grade in a well pit or other suitable enclosure Do not locate in an area where leaking or f...

Page 4: ...valve on the outgoing line This will allow the Well X1 to be tested prior to pressurizing the entire system DO NOT place a shutoff on the incoming supply line NOTE The relief valve is sized for a max...

Page 5: ...conduit connections and wire nuts for an outside application 3 Wiring is similar to a traditional mechanical pressure switch Two leads are connected to line supply while the other supply the pump moto...

Page 6: ...above 10 psig Depressing the s arrow will temporarily override the low water cut off to allow proper priming 5 The factory cut out pump off setting is 60 psig When the pump reaches 60 psig the Well X1...

Page 7: ...K AND SET CUT IN 5 To adjust the cut out depress once and the display will read HI Again press thetor s buttons to raise or lower the setting The same 10 55 psig differential range applies Maximum set...

Page 8: ...oo high 2 Recurring error 1 Adjust air pressure 2 psi below cut in setting 2 See Error Code section for possible causes No pressure pump runs 1 No pump prime jet pumps 2 Failing well pump 3 Incorrect...

Reviews: