DANGER! EXPLOSION HAZARD.

 WHEN THE 

WELL TANK HAS BEEN IN SERVICE AND A 

CHANGE TO A HIGHER PRE-CHARGE PRESSURE IS NECESSARY 

DUE TO A REQUIRED CHANGE IN THE PRESSURE SWITCH 

SETTING, FAILURE TO FOLLOW INSTRUCTIONS BELOW CAN 

CAUSE A RUPTURE OR EXPLOSION, POSSIBLY CAUSING SERIOUS 

OR FATAL PERSONAL INJURY, AND/OR PROPERTY DAMAGE.
  • DO NOT ADJUST OR ADD PRESSURE IF THERE HAS BEEN A 

LOSS OF AIR.

  • DO NOT ADJUST THE PRE-CHARGE PRESSURE IF THERE IS 

VISIBLE EXTERIOR CORROSION.

  • DO NOT ADJUST THE PRE-CHARGE PRESSURE IF THERE HAS 

BEEN A REDUCTION OF THE PUMP CYCLE TIME OR THE PRE-

CHARGE PRESSURE COMPARED TO ITS INITIAL SETTING. 

THIS IS BECAUSE REDUCTION IN PUMP CYCLE TIME CAN 

RESULT FROM LOSS OF TANK AIR PRESSURE WHICH IN 

TURN CAN MEAN THERE MAY BE INTERNAL CORROSION AND 

ANY RE-PRESSURIZATION OR ADDITIONAL PRESSURE COULD 

RESULT IN RUPTURE OR EXPLOSION. 

MAXIMUM WORKING PRESSURES.

 Every Well-X-Trol 

is air tested to 150 psig, the maximum working 

pressure for the Well-X-Trol line.

RELIEF VALVE REQUIRED.

  A relief valve should 

be installed which is set to open at  excessive 

pressures (100 psig or more). This will protect the Well-X-Trol

 

and other 

system components should the pressure switch malfunction and fail to 

shut the pump off.  The relief valve should be installed at the connection 

of the Well-X-Trol to the system piping and have a discharge equal to 

the pump’s capacity at 100 psig. 

AS IN ALL PLUMBING PRODUCTS AND WATER 

STORAGE VESSELS, BACTERIA CAN GROW IN 

YOUR WELL TANK, ESPECIALLY DURING TIMES OF NON-USE. 

CONSULT YOUR LOCAL PLUMBING OFFICIAL REGARDING ANY 

STEPS YOU MAY WISH TO TAKE TO SAFELY DISINFECT YOUR 

HOME’S PLUMBING SYSTEM.

The pump controller is not a disconnect. The pump 

may be activated at any time. The electrical system 

must be considered energized at all times unless  the circuit breaker is 

open. The disconnect for the controller must break all incoming power 

lines. As with a mechanical pressure switch, when installed with three wire 

230 vac pumps or any 3-phase pump, a standard pump motor starter or a 

relay must be used.

A water test must be taken before installation of any 

water treatment equipment.

DANGER!  EXPLOSION HAZARD.

  IF YOU 

ADJUST THE PRE-CHARGE PRESSURE OR ADD 

PRESSURE TO A TANK THAT IS CORRODED OR DAMAGED OR 

WITH DIMINISHED INTEGRITY THE TANK CAN BURST OR EXPLODE, 

POSSIBLY CAUSING SERIOUS OR FATAL PERSONAL INJURY AND/

OR PROPERTY DAMAGE.
  • ONLY ADJUST THE PRE-CHARGE AS DESCRIBED IN THIS 

MANUAL WHEN THE TANK IS NEW OR WHEN THE INTEGRITY OF 

THE TANK AND LACK OF INTERNAL OR EXTERNAL CORROSION 

IS CONFIRMED.

  • ONLY LICENSED PROFESSIONALS SHOULD CHECK, ADJUST 

OR RE-CHARGE THE PRE-CHARGE OF TANKS.

For your safety, the information in this manual must 

be followed to minimize the risk of electric shock, 

property damage or personal injury.

• Properly ground to conform with all governing codes and ordinances.

Do not install in direct sunlight. Excessive sun heat 

may cause distortion or other damage to non-

metallic parts.

Use only lead-free solder and flux for all sweat-

solder connections, as required by state and 

 

federal codes.

Maximum allowable inlet water pressure is 125 

psig.  If daytime pressure is over 80 psig, nighttime 

pressure may exceed the maximum. Use a pressure-reducing valve to 

reduce the flow if necessary.

ELECTROCUTION AND EXPLOSION HAZARD.

 

before work is performed on the tank, turn off the 

power to the pump and release all water pressure in the tank and 

pumping system.

This control is capable of running pumps to pressures 

that may exceed the limitations of system 

components. Never set the operation pressure higher than that of the safe 

system capacity.

This control can be adjusted to a narrow pressure  

differential. This can cause the pump to cycle rapidly 

with an improperly sized tank, leading to pump damage. This may require 

a larger pressure tank than normally used. 

PLEASE READ THE FOLLOWING INSTRUCTIONS CAREFULLY

IMPORTANT GENERAL SAFETY INFORMATION - 

ADDITIONAL SPECIFIC SAFETY ALERTS APPEAR IN THE FOLLOWING INSTRUCTIONS.

Summary of Contents for WELL-X-TROL WELL-X1

Page 1: ...not locate in an area where leakage of the tank or connections could cause property damage to the area adjacent to the appliance or to lower floors of the structure EXPLOSION OR RUPTURE HAZARD A reli...

Page 2: ...with a mechanical pressure switch when installed with three wire 230 vac pumps or any 3 phase pump a standard pump motor starter or a relay must be used A water test must be taken before installation...

Page 3: ...n above ground only Do not install horizontally or directly bury the unit The Well X1 may be installed below grade in a well pit or other suitable enclosure Do not locate in an area where leaking or f...

Page 4: ...valve on the outgoing line This will allow the Well X1 to be tested prior to pressurizing the entire system DO NOT place a shutoff on the incoming supply line NOTE The relief valve is sized for a max...

Page 5: ...conduit connections and wire nuts for an outside application 3 Wiring is similar to a traditional mechanical pressure switch Two leads are connected to line supply while the other supply the pump moto...

Page 6: ...above 10 psig Depressing the s arrow will temporarily override the low water cut off to allow proper priming 5 The factory cut out pump off setting is 60 psig When the pump reaches 60 psig the Well X1...

Page 7: ...K AND SET CUT IN 5 To adjust the cut out depress once and the display will read HI Again press thetor s buttons to raise or lower the setting The same 10 55 psig differential range applies Maximum set...

Page 8: ...oo high 2 Recurring error 1 Adjust air pressure 2 psi below cut in setting 2 See Error Code section for possible causes No pressure pump runs 1 No pump prime jet pumps 2 Failing well pump 3 Incorrect...

Reviews: