INSTALLATION - WIRING

1.

  Shut off the circuit breaker for the well system. Loosen 

the silver screw on top of the control and remove cover 

to expose the control wires.

 

Electrocution  hazard.

 For your 

safety, the information in this manual 

must be followed to minimize the risk of electric shock, 

property damage or personal injury. Properly ground 

to conform with all governing codes and ordinances. 

2.

  The 12 gauge wire leads are pre-stripped and ready 

to accept standard wire nuts. Each wire is color 

coded to correspond with the diagram below. Use 

water tight conduit, connections, and wire nuts for an  

outside application.

3.

  Wiring is similar to a traditional mechanical pressure 

switch. Two leads are connected to line supply, while 

the other supply the pump motor or starter. Wire the 

control to the line supply and pump motor or pump 

starter as required by the manufacturer's instructions. 

It is recommended that service switch be installed in 

addition to the circuit breaker. The disconnect for the 

controller must break all incoming power lines. This 

should interrupt line voltage and be installed near the 

Well-X1

®

 and labeled appropriately. 

4.

  After completing the wiring, reattach top cover and 

tighten screw. Ensure no loose wires protrude from  

the control.

LINE

LINE

MOT

OR

MOT

OR

BLACK

WHITE/STRIPE

BLUE

WHITE

SCREW

Summary of Contents for WELL-X-TROL WELL-X1

Page 1: ...not locate in an area where leakage of the tank or connections could cause property damage to the area adjacent to the appliance or to lower floors of the structure EXPLOSION OR RUPTURE HAZARD A reli...

Page 2: ...with a mechanical pressure switch when installed with three wire 230 vac pumps or any 3 phase pump a standard pump motor starter or a relay must be used A water test must be taken before installation...

Page 3: ...n above ground only Do not install horizontally or directly bury the unit The Well X1 may be installed below grade in a well pit or other suitable enclosure Do not locate in an area where leaking or f...

Page 4: ...valve on the outgoing line This will allow the Well X1 to be tested prior to pressurizing the entire system DO NOT place a shutoff on the incoming supply line NOTE The relief valve is sized for a max...

Page 5: ...conduit connections and wire nuts for an outside application 3 Wiring is similar to a traditional mechanical pressure switch Two leads are connected to line supply while the other supply the pump moto...

Page 6: ...above 10 psig Depressing the s arrow will temporarily override the low water cut off to allow proper priming 5 The factory cut out pump off setting is 60 psig When the pump reaches 60 psig the Well X1...

Page 7: ...K AND SET CUT IN 5 To adjust the cut out depress once and the display will read HI Again press thetor s buttons to raise or lower the setting The same 10 55 psig differential range applies Maximum set...

Page 8: ...oo high 2 Recurring error 1 Adjust air pressure 2 psi below cut in setting 2 See Error Code section for possible causes No pressure pump runs 1 No pump prime jet pumps 2 Failing well pump 3 Incorrect...