3

CONTROL

AIR CHARGING

VALVE

TANK

TUBING

DRAIN

COMPONENTS

SIZING

1.  STANDARD OPERATION: 20 PSI DIFFERENTIAL

2.  CONSTANT PRESSURE MODE: 10 PSI DIFFERENTIAL

The Well-X1

®

 functions like a traditional pressure switch by cycling the pump on and off. The factory pressure settings are 

40 psi cut-in and 60 psi cut-out. The controller allows these settings to be adjusted to best suit the application. The Well-X1

 

can operate in two primary modes:

LOCATION

The Well-X1 is designed for indoor and outdoor installations. 

If installed outdoors:

• Do not install where ambient temperatures can drop 

below freezing or exceed 130° F.

• 

Use water-tight wiring conduit, wire nuts and 

conduit connections as dictated by applicable codes  

and ordinances.

•  Protect the piping from mechanical damage.

• Install the relief valve blow down tube where venting 

water will not cause personal injury or damage the  

surrounding property.

• Drip Pan and Drain: To avoid leaking and/or property 

damage, install with a drip pan connected to an adequate 

working drain kept clear at all times.

ORIENTATION

Ensure the installation meets all applicable local codes 

and is installed by a licensed professional. Additionally, the 

following should be noted.

•  This unit is designed for vertical installation above ground 

only. Do not install horizontally or directly bury the unit. 

The Well-X1 may be installed below grade in a well pit or 

other suitable enclosure. 

Do not locate in an area where 

leaking or flooding could cause property damage to 

surrounding areas.

• Check codes to determine if there are any height 

requirements pertaining to the Well-X1. 

 

Particularly, 

ensure the bottom drain meets these requirements. 

If restrictions are imposed on the proximity of drain 

connections  to  the  floor,  the  unit  may  be  elevated  on 

blocks or the bottom drain tube can be removed and 

plugged, after which a sampling tap may be installed in 

the water lines near the top of the Well-X1.

WELL-X1 SELECTION FOR CONSTANT PRESSURE

Control Setting (cut-in/cut-out) (psi)

 

40/50

50/60

60/70

70/80

PUMP

 GPM

4

WX1-250

WX1-250

WX1-250

WX1-250

5

WX1-250

WX1-250

WX1-250

WX1-250

7

WX1-250

WX1-250

WX1-251

WX1-251

10

WX1-251

WX1-251

WX1-302

WX1-302

12

WX1-251

WX1-302

WX1-302

WX1-302

15

WX1-302

WX1-302

-

-

WELL-X1

 

SELECTION FOR STANDARD SYSTEMS

Control Setting (cut-in/cut-out) (psi)

 

30/50

40/60

50/70

60/80

PUMP

 GPM

4

WX1-250

WX1-250

WX1-250

WX1-250

5

WX1-250

WX1-250

WX1-250

WX1-250

7

WX1-250

WX1-250

WX1-250

WX1-250

10

WX1-250

WX1-250

WX1-250

WX1-251

12

WX1-250

WX1-250

WX1-251

WX1-251

15

WX1-251

WX1-251

WX1-302

WX1-302

18

WX1-251

WX1-302

WX1-302

WX1-302

20

WX1-302

WX1-302

WX1-302

-

PRE-INSTALLATION

COVER

RELIEF VALVE

GUARDIAN CP

 

CONTROL WITH 

NEMA3 ENCLOSURE

WATER

CONNECTIONS(2)

Summary of Contents for WELL-X-TROL WELL-X1

Page 1: ...not locate in an area where leakage of the tank or connections could cause property damage to the area adjacent to the appliance or to lower floors of the structure EXPLOSION OR RUPTURE HAZARD A reli...

Page 2: ...with a mechanical pressure switch when installed with three wire 230 vac pumps or any 3 phase pump a standard pump motor starter or a relay must be used A water test must be taken before installation...

Page 3: ...n above ground only Do not install horizontally or directly bury the unit The Well X1 may be installed below grade in a well pit or other suitable enclosure Do not locate in an area where leaking or f...

Page 4: ...valve on the outgoing line This will allow the Well X1 to be tested prior to pressurizing the entire system DO NOT place a shutoff on the incoming supply line NOTE The relief valve is sized for a max...

Page 5: ...conduit connections and wire nuts for an outside application 3 Wiring is similar to a traditional mechanical pressure switch Two leads are connected to line supply while the other supply the pump moto...

Page 6: ...above 10 psig Depressing the s arrow will temporarily override the low water cut off to allow proper priming 5 The factory cut out pump off setting is 60 psig When the pump reaches 60 psig the Well X1...

Page 7: ...K AND SET CUT IN 5 To adjust the cut out depress once and the display will read HI Again press thetor s buttons to raise or lower the setting The same 10 55 psig differential range applies Maximum set...

Page 8: ...oo high 2 Recurring error 1 Adjust air pressure 2 psi below cut in setting 2 See Error Code section for possible causes No pressure pump runs 1 No pump prime jet pumps 2 Failing well pump 3 Incorrect...

Reviews: