INSTALLATION - PLUMBING

1.

  Plumbing connections are similar to a traditional tank 

cross or tank tee. Provisions are made for popular 

line sizes via a 1-1/4" NPT male outer thread and a 1" 

NPT female inner thread. The plumbing connections 

are  not  directional  and  allow  flow  from  either  side. 

When  attaching  valves  or  fittings,  uses  the  wrench  

flats provided.

 

EXPLOSION HAZARD.

 Failure to 

follow these instructions can cause a 

rupture or explosion possibly causing serious or fatal 

injury, flooding, and/or property damage.

2. 

Install the supply piping from the well pump. If required, 

install a spring-loaded check valve. Install a shutoff 

(service) valve on the outgoing line. This will allow the 

Well-X1

®

 to be tested prior to pressurizing the entire 

system. DO NOT place a shutoff on the incoming  

supply line.

 

NOTE: 

The  relief  valve  is  sized  for  a  maximum  flow 

rate of 10 gpm at 125 psi. If the pump installation 

allows higher flow rates, an additional relief valve must  

be installed.

3. 

Connect the water line from the well pump to the inlet of 

the Well-X1. Plumb the outgoing supply to the building’s 

water supply system or into the water treatment 

equipment (if present).

4. 

Install a blow down tube from the relief valve to a drain or 

to within 6" of the floor as required by local codes.

 

A drip pan connected to an adequate 

drain must be installed if leaking or 

flooding could cause property damage.

WATER
CONNECTIONS

CHECK 

VALVE

SHUT

OFF

TO
SYSTEM

FROM

WELL

RELIEF
VALVE

BLOWDOWN
TUBE

6”

Summary of Contents for WELL-X-TROL WELL-X1

Page 1: ...not locate in an area where leakage of the tank or connections could cause property damage to the area adjacent to the appliance or to lower floors of the structure EXPLOSION OR RUPTURE HAZARD A reli...

Page 2: ...with a mechanical pressure switch when installed with three wire 230 vac pumps or any 3 phase pump a standard pump motor starter or a relay must be used A water test must be taken before installation...

Page 3: ...n above ground only Do not install horizontally or directly bury the unit The Well X1 may be installed below grade in a well pit or other suitable enclosure Do not locate in an area where leaking or f...

Page 4: ...valve on the outgoing line This will allow the Well X1 to be tested prior to pressurizing the entire system DO NOT place a shutoff on the incoming supply line NOTE The relief valve is sized for a max...

Page 5: ...conduit connections and wire nuts for an outside application 3 Wiring is similar to a traditional mechanical pressure switch Two leads are connected to line supply while the other supply the pump moto...

Page 6: ...above 10 psig Depressing the s arrow will temporarily override the low water cut off to allow proper priming 5 The factory cut out pump off setting is 60 psig When the pump reaches 60 psig the Well X1...

Page 7: ...K AND SET CUT IN 5 To adjust the cut out depress once and the display will read HI Again press thetor s buttons to raise or lower the setting The same 10 55 psig differential range applies Maximum set...

Page 8: ...oo high 2 Recurring error 1 Adjust air pressure 2 psi below cut in setting 2 See Error Code section for possible causes No pressure pump runs 1 No pump prime jet pumps 2 Failing well pump 3 Incorrect...

Reviews: