User's Guide 21
Label Sensor Calibration Procedure
The Label Sensor Calibration procedure allows the printer to calibrate the Label Sensor to the media
type and length being used. The Label Sensor in this procedure looks at the back of the media sensing
for:
Black Bar Media
Gap Media
Or, Continuous Feed Media
1.
Power the printer on while pressing the Feed button on the front panel.
2.
When the feed motor begins moving, release the “FEED” button.
3.
The printer will feed approximately 12 inches of blank media.
4.
Once the printer has stopped feeding the user can, open the printhead module and manually
reverse feed the media back to the first label.
5.
Press the Feed button again to align the media to the top of the next label.
Notes:
These steps are very important and must always be carried out after the first installation and
each time the media type (color, size, backing, etc) is changed. Failure to run the Label
Sensor Calibration test may result in the label registration errors and label-empty detection
being incorrect.
Summary of Contents for Fastmark 400 Series
Page 1: ...Fastmark 400 Series Barcode Label Printer User s Guide Part No 110021 A ...
Page 7: ...User s Guide 6 this page intentionally left blank ...
Page 58: ...User s Guide 57 ...
Page 59: ...User s Guide 58 ...
Page 61: ...User s Guide 60 ...
Page 63: ...User s Guide 62 ...
Page 64: ...User s Guide 63 ...
Page 65: ...User s Guide 64 ...
Page 67: ...User s Guide 66 ...
Page 68: ...User s Guide 67 ...
Page 69: ...User s Guide 68 ...
Page 71: ...User s Guide 70 Symbol Set ...
Page 72: ...User s Guide 71 ...
Page 73: ...User s Guide 72 ...
Page 75: ...User s Guide 74 ...