FLEECEBACK & INSULATION MOBILE ADHESIVE DISPENSING CART
800.620.7928
PAGE 11
WWW.PATRIOTJR.COM
Fusion Gun Overnight Shut Down
1. Turn off rocker switch on pump. Unplug Unit.
2. Turn down pressure knob to off position on pump.
3. Shut off valves on gunblock.
4. Allow air to blow through gun for 5 minutes.
5. Trigger gun a few times to help clear tip.
6. Shut off air compressor.
7. Remove air line from gun.
8. Remove cap from top of grease fitting on gun until grease comes out of gun end.
9. Replace cap.
10. Store gun in a dry bag.
11. Turn off both ball valves at inlet hoses from drums.
12. Insert plugs back on vent tubes.
13. Cover Patriot Jr. with green stock cover provided.
Note: Suggested times for shut down
Lunch breaks, Overnight, 3-5 days