This manual is an important part of your machine and should remain with the machine at all times for continued
reference on proper use and care of this machine.
01. Open drums and insert fittings. Fittings for drum should correspond to fitting on PJR Reactor.
Be sure to set drums up to match stickers and labels.
Never change product once designated and used in lines and PJR Reactor.
02. Mount PJR Reactor on PJR Cart.
MAKE SURE ALL CLIPS AND HOLD DOWNS ARE SECURE!!!!
03. Stand PJR Cart upright with the help of another person.
DO NOT ATTEMPT ON YOUR OWN.
04. Line drums up according to labels and fitting location.
Small cam lock fittings should face the bottom of the cart.
05. Make sure valves are closed and vents remain plugged.
06. Roll drums into place.
07. Secure drums using the provided ratchet straps.
Make sure drum straps are in the locked position and the drums are firmly against the deck.
08. Connect cam lock fitting to drums. Ensure all fittings are connected securely and are in the locked position.
PLEASE DOUBLE CHECK ALL FITTINGS AND CLIPS.
09. With the help of another person, pull PJR Cart down from the upright position, so the drums are parallel with the roof deck and
the wheels and rear legs are on the surface securely.
10. Place Generator in tray.
11. Connect all hoses and gun making sure that the hoses are in the proper place.
Hose fittings will only fit in one way.
12. Make sure all fittings are secure and firm.
13. Start Generator and plug PJR Reactor into power. Allow time to warm up.
DO NOT USE IDLE CONTROL / ECOSWITCH ! Generator should run at full throttle all the time to prevent damage to PJR Reactor.
14. Install Driers into vent fittings.
It may be necessary to use bleed lines into vent fittings first.
15. Put bleed valves in “spray” position. and turn dial to 1-2 with gun open.
16. Make sure fluids are flowing through clear tubing. Open valves allowing product to flow into pumps.
17. Install Static Nozzle and begin spraying.
18. Run until even flow comes through gun end on both sides. When in use to prevent clogging at tip purge gun every 1-2 mins/or as
necessary so adhesive does not clog.
FLEECEBACK & INSULATION MOBILE ADHESIVE DISPENSING CART
PAGE 07
WWW.PATRIOTJR.COM
800.620.7928
Startup Procedures
NOTE:
To change drums reverse procedure.