3A1602J
Controls and Indicators
Power Switch
Powers the Reactor E-8p on and off.
Motor/Pump Control Function Knob
Use knob to select desired function.
STATUS Indicator
Indicates system status, including power and error
codes.
•
Indicator steady on: power switch is turned on.
•
Indicator blinking: If an error occurs, the status indi-
cator light will blink one to seven times to indicate a
specific status code, pause, and then repeat. The
following table provides a brief description of each
status code. For more detailed information and cor-
rective action, see Status Codes on page 27.
NOTE: The default is to shut down if a status code indi-
cation occurs. Codes 1 and 2 may be set to disable
automatic shutdown if desired; see page 28. You cannot
set the other codes.
F
IG
. 2: Controls and Indicators
I
-
-
+
-
Power
Switch
Status Indicator
Motor/Pump Control Function Knob
Status
Codes
TI17123b
Icon
Setting
Function
Stop/Park
Stops motor and automati-
cally parks pumps.
Slow Recirc
Slow recirculation speed.
Fast Recirc
Fast recirculation speed.
Static Mix
Use fluid pressure settings
1-5 to dispense polyurea
joint-fill materials through a
static mixer.
Spray
Use fluid pressure settings
6-10 to spray polyurethane
foam.
Table 1
: Status Codes
(also located on front of Reactor)
Code
Code Name
1
Pressure imbalance between A and B sides
2
Unable to maintain pressure setpoint
3
Pressure transducer A failure
4
Pressure transducer B failure
5
Excessive current draw
6
High motor temperature
7
No cycle counter switch input
FLEECEBACK & INSULATION MOBILE ADHESIVE DISPENSING CART
800.620.7928
PAGE 29
WWW.PATRIOTJR.COM
Summary of Contents for P-55
Page 1: ......