VOICECOM USER MANUAL ISSUE 4
-18-
Display and Main Menu Page
When power is applied to the VCA the display defaults to the Main Menu page, shown in Figure 11. The backlight will
turn on and remain active for 5 minutes after the last key press. Pressing any of the 7 keys will turn the backlight on.
If not on the Main Menu page, the display will return back to the Main Menu page if no key is pressed for 5 minutes
and the backlight will turn off.
NOTE:
The only exception to this is when downloading Message Bank files. The display does not move off of the
VCA Message Bank page when a connection between the VCA and a PC has been established.
1
Menu level number (on all pages)
4 Name of message currently playing
2
VCA Firmware version
5 Line 1 status messages and alarms
3
Number of audio message currently playing
6 Line 2 status messages and alarms
Below are a list of the status and alarm messages that can be displayed for LINE 1 and LINE 2.
Table 11 - VCA Alarm Messages
Message
Description
VAAs Replying OK
The number of VAAs that the VCA can communicate with matches the “
# of
VAAs to be online
” parameter.
VAA Reply # Alarm
The number of VAAs that the VCA can communicate with is greater/less
than the “
# of VAAs to be online
” parameter.
Address Clash
Two or more VAAs have the same address.
No VAAs Enabled
The “
# of VAAs to be online
” parameter is set to “
None
”.
PSW Active
A pre-start alarm is active.
PSW Healthy
The pre-start alarm has been successful. All the required VAAs confirmed
sounding the pre-start alarm.
PSW Blocked
The maximum pre-start initiation time has been exceeded (30 seconds).
Remove the pre-start alarm input and reapply to sound the pre-start alarm
again. For every second that the pre-start alarm input is removed three
seconds of pre-start alarm can be sounded if the input is reapplied. See the
Pre-Start Alarm Operation chapter for more information on the operation of
the pre-start alarm.
There are also a couple of VCA fault message that can appear on the second line of the display on the Main Menu
page. Refer to the Troubleshooting chapter for more information on VCA faults.
Table 92 - VCA Hardware Fault Alarms
Message
Description
VCA mem. Error
An error has occurred with the VCA configuration memory.
Msg.Proc. Fail
A fault has occurred with the VCA Message Bank hardware.
1 VCA4V02 2003 Msg#
Iso at sta 1 13
L1:VAAs Replying OK
L2:No VAAs Enabled
1
2
3
4
5
6
Figure 11 - Main Menu Page
Summary of Contents for VAA
Page 73: ...VOICECOM USER MANUAL ISSUE 4 77 APPENDIX G I S Approvals ...
Page 74: ...VOICECOM USER MANUAL ISSUE 4 78 ...
Page 75: ...VOICECOM USER MANUAL ISSUE 4 79 ...
Page 76: ...VOICECOM USER MANUAL ISSUE 4 80 ...
Page 77: ...VOICECOM USER MANUAL ISSUE 4 81 ...
Page 78: ...VOICECOM USER MANUAL ISSUE 4 82 ...
Page 79: ...VOICECOM USER MANUAL ISSUE 4 83 ...