VOICECOM USER MANUAL ISSUE 4
-9-
NOTE
: Pre-start alarms
cannot
be initiated via Modbus. The PSR1 and PSR2 inputs must be used to initiate pre
start alarms on Lines 1 and 2.
Table 1 - Connections for Digital Input/Modbus Mode
Terminal
Function
DI1 to DI12
Momentarily apply +24VDC (edge triggered inputs) to play voice messages 1 to 12
respectively
PSR1
Apply +24VDC to input and hold to play pre-start alarm down line 1
PSR2
Apply +24VDC to input and hold to play pre-start alarm down line 2
0V DI
0V common for all digital inputs (from negative side of 24VDC supply)
Table 2 - Connections for Strobe Mode
Terminal
Function
DI1 to DI8
Set up message address in binary where DI1 is the least significant bit. Apply and
hold +24VDC to the inputs until strobe input has been asserted.
DI9
Momentarily apply +24VDC (edge triggered input) to play the message once the
message address has been set up using inputs DI1 to 8.
DI10 to 12
Not used – no connection
PSR1
Apply +24VDC to input and hold to play pre-start alarm down line 1
PSR2
Apply +24VDC to input and hold to play pre-start alarm down line 2
0V DI
0V common for all digital inputs (from negative side of 24VDC supply)
Table 3 - Connections for Modbus Mode
Terminal
Function
DI1 to DI12
Not used – no connection
PSR1
Apply +24VDC to input and hold to play pre-start alarm down line 1
PSR2
Apply +24VDC to input and hold to play pre-start alarm down line 2
0V DI
0V common for all digital inputs (from negative side of 24VDC supply)
Summary of Contents for VAA
Page 73: ...VOICECOM USER MANUAL ISSUE 4 77 APPENDIX G I S Approvals ...
Page 74: ...VOICECOM USER MANUAL ISSUE 4 78 ...
Page 75: ...VOICECOM USER MANUAL ISSUE 4 79 ...
Page 76: ...VOICECOM USER MANUAL ISSUE 4 80 ...
Page 77: ...VOICECOM USER MANUAL ISSUE 4 81 ...
Page 78: ...VOICECOM USER MANUAL ISSUE 4 82 ...
Page 79: ...VOICECOM USER MANUAL ISSUE 4 83 ...