Electrical Connections
•
A qualified and trained electrician should make the electrical connection to the motor.
•
Use safety equipment when manipulating electricity.
•
Use appropriate signs in areas where electrical equipment is exposed.
•
The pump must be disconnected and secured to prevent startup before starting any work
on electrical equipment.
•
Use the proper wire number in accordance to the motor voltage and amperage.
•
Follow diagram connections shown on the motor nameplate; check the motor installation
manual for any questions.
•
Isolate and protect the terminal ports and connections.
•
Make sure the rotation of the pump is correct.
•
The motor of your pump has been tested and was selected to meet the requirements of a
specific application. The motor amperage consumption should be within the range indicated on
the motor nameplate for proper operation.
•
The user is responsible for the safety and proper operation of equipment when special or other
motors are used (not supplied by Ampco).
Temperature
The QTS Series is designed to work in a normal temperature range between -40 °C (-40 °F) and
100 °C (212 ° F). Be careful when touching the body and gear case to avoid burns when the
temperature rises. If the application requires a higher temperature range please contact Ampco
Pumps for further information regarding the application
Moving Parts
The principal operation of the QTS Series is the rotation of a pair of synchronized rotors which can
trap foreign objects and get stuck due to improper equipment operation. Never operate the pump
without the front cover properly in place.
The gearbox contains rotating parts; never operate the pump without the gear case cover. Use
caution around rotating shaft elements. Likewise, do not operate the pump without the coupling
guard in position.
Lifting the Pump
Carefully transport the equipment avoiding contact, drops, or damage. To prevent damage, the
QTS Series is equipped with an eye bolt located on the gear case for lifting.