After CIP cleaning, an additional sterilization in place process (SIP) may be required when highly
sensitive products are handled, inactivating any micro-organisms which might be still present in
the pump. The sterilization can be carried out by means of chemicals, hot water or steam. In
the dairy industry the sterilization temperature is approximately 145 °C (293 °F). Contact Ampco
Pumps in cases where temperatures will exceed 100 ºC (212 ºF).
Because the QTS pump is capable of high speeds it is important to specify the required RPM
values for CIP supply if available.
Normally when ordered, the QTS Pump is selected for both, the application and CIP supply.
RPM speed table for each pump model.
dimensions:
Flow required to achieve the CIP process in different pipe
Pipe Diameter
1.5
2.0
2.5
3.0
4.0
6.0
QTS102 - 1.5 m/s
1146
2100
3372
QTS102 - 3.0 m/s
2291
QTS103 - 1.5 m/s
1707
3133
QTS103 - 3.0 m/s
3414
QTS202 - 1.5 m/s
799
1281
1418
QTS202 - 3.0 m/s
1598
2562
QTS203 - 1.5 m/s
1188
1906
2149
QTS203 - 3.0 m/s
2375
QTS302 - 1.5 m/s
532
780
1418
QTS302 - 3.0 m/s
1064
1562
QTS303 - 1.5 m/s
807
1183
2149
QTS303 - 3.0 m/s
1612
2370