3.6.25. How to exchange CLArK gearbox oil
Remove plug, drain oil to a prepared vessel of 21,5 l (5,7 gal
•
US) and at the same time replace filter as per Section named
“How to Replace Filter”.
Open the cover underneath control panel.
•
Pour the amount of 21,5 l (5,7 gal US) through a hole after
•
having pulled out check dipstick, up to FULL mark. Start the
engine and while idling, check oil level to confirm it reaches
up to ADD mark. With oil warmed up to 82÷93 °C, please
check and fill up to FULL if required.
Drain oil when operation has ended af-
ter cooling down to 50 °C, or while driv-
ing you wait until oil warms up.
Beware of burn hazard when draining
hot oil .
Observe fire precautions!
Use recommended oils according to
Section 3.2.5.
Drain oil into collection vessels.
Spent oil is ecological waste – hand over
for disposal.
Summary of Contents for AP 240
Page 1: ...Book ID 4 P06430CU AP 240 Cummins EN Operating manual...
Page 2: ......
Page 4: ......
Page 5: ...M sto a datum vyd n Place and date of issue Ort und Datum der Ausgabe...
Page 6: ......
Page 14: ...8 AP 240...
Page 15: ...9 AP 240 SPECIFICATION MANUAL 1 SPECIFICATION MANUAL AP 240 Cummins Tier 3...
Page 24: ...18 AP 240 Notes...
Page 25: ...19 AP 240 SPECIFICATION MANUAL Notes...
Page 26: ...20 AP 240...
Page 27: ...21 AP 240 OPERATION MANUAL 2 OPERATION MANUAL AP 240 Cummins Tier 3...
Page 28: ...22 AP 240...
Page 88: ...82 AP 240 Notes...
Page 89: ...83 AP 240 OPERATION MANUAL Notes...
Page 90: ...84 AP 240...
Page 91: ...85 AP 240 MAINTENANCE MANUAL 3 MAINTENANCE MANUAL AP 240 Cummins Tier 3...
Page 92: ...86 AP 240...
Page 156: ...150 AP 240...
Page 166: ...160 AP 240 3 8 Annexes Notes...
Page 167: ...161 AP 240 MAINTENANCE MANUAL Notes...
Page 168: ...162 AP 240 3 8 Annexes Notes...
Page 169: ......