43
AP 240
OPErATION MANUAL
Ignition box (1)
In ”0” position the Machine lighting will be connected along
with hand lamp socket. In ”I” position other consumers will be
connected. Spring-loaded position ”II” is used to start the en-
gine. Key can be removed in ”0” position only.
Note:
The key is identical to the key for locking the cabin door.
Travel controller (2)
It is used to adjust direction of running and for gear shifting via
a turning handle.
“F“ position - forward
“N“ position - idle (neutral)
“R“ position - backward
Horn pushbutton and fuse are part of the controller.
Position of “N“ fuse – controller interlocking.
2185
sta06
3397
0
I
3397
2582
2657
3003
2658
I
II
III
IV
0
2659
595200
2701
Inflation valve (3), deflation valve (4)
It is used to make up or deflate tyre air.
For pressure values, please refer to the
Table in Section named Tyre Pressure
Control.
Do NOT switch ON both valves simulta-
neously to ”I” position!
gearbox oil pressure gauge (5)
Operating oil medium pressure must move with-
in 12,5-15,5 bar range.
! CAUTION !
When pressure drops below 12,5 bar, stop the
Machine.
gearbox oil temperature (6)
Operating temperature may move within 80 -
120 °C range. Max temperature is 120 °C.
Power view display (7)
Multifunctional instrument to display engine function and fuel
reading.
Brake circuit pressure gauge (8)
White indicator shows air pressure inside air res-
ervoir - adjusted to max 8 bar.
Red one indicates air pressure when braking - air
pressure from air brake valve to brake booster.
Tire pressure gauge (9)
The minimum air pressure after air release from
tyres has been adjusted to 1,5-2 bars.
TOTAL STOP (10)
Press to stop the Machine and its engine instant-
ly in emergency event.
Indication of workplace enabled (11)
Indicates from which position (seat) the Roller travel is con-
•
trolled.
If no indicator lamp (11) flashes with the ignition box key
•
turned ON then the engine can be started. If indicator lamps
(11) flash with the ignition key turned ON, then the engine
cannot be started since one or two travel controllers are not
in N position - idle indicator lamp does not light.
Sprinkling interval control (12)
Turn the switch left to start up the pump to run
continuously - tires will be sprinkled constantly.
Turn the switch to any of four positions in clock-
wise direction to turn ON sprinkling interval con-
trol.
Position I sprinkling for 10 s dwell for 10 s
Position II sprinkling for 10 s dwell for 15 s
Position III sprinkling for 10 s dwell for 22 s
Position IV sprinkling for 10 s dwell for 33 s
Sprinkling indicator lamp will light only when
pump is running.
Socket (13) - to connect to ECM (Electronic
Control Module) designed to diagnose any
defects or to adjust engine parameters.
Trimmer (14) - downward, upward - optional
Direction-indicator lights (15)
Summary of Contents for AP 240
Page 1: ...Book ID 4 P06430CU AP 240 Cummins EN Operating manual...
Page 2: ......
Page 4: ......
Page 5: ...M sto a datum vyd n Place and date of issue Ort und Datum der Ausgabe...
Page 6: ......
Page 14: ...8 AP 240...
Page 15: ...9 AP 240 SPECIFICATION MANUAL 1 SPECIFICATION MANUAL AP 240 Cummins Tier 3...
Page 24: ...18 AP 240 Notes...
Page 25: ...19 AP 240 SPECIFICATION MANUAL Notes...
Page 26: ...20 AP 240...
Page 27: ...21 AP 240 OPERATION MANUAL 2 OPERATION MANUAL AP 240 Cummins Tier 3...
Page 28: ...22 AP 240...
Page 88: ...82 AP 240 Notes...
Page 89: ...83 AP 240 OPERATION MANUAL Notes...
Page 90: ...84 AP 240...
Page 91: ...85 AP 240 MAINTENANCE MANUAL 3 MAINTENANCE MANUAL AP 240 Cummins Tier 3...
Page 92: ...86 AP 240...
Page 156: ...150 AP 240...
Page 166: ...160 AP 240 3 8 Annexes Notes...
Page 167: ...161 AP 240 MAINTENANCE MANUAL Notes...
Page 168: ...162 AP 240 3 8 Annexes Notes...
Page 169: ......