41
V. TEST RUN
1. Adjust synchronous cable
(See Fig. 54)
Use wrench to hold the cable fitting, meanwhile
use ratchet spanner to tighten the cable nut.
Make sure two cables are with the same tension
so that two carriages can work synchronously.
Fit the plastic hole cover on the lifting head.
If the carriage does not Synchronize when lifting,
please tighten the cable nut of lower side carriage.
2. Adjust Safety Cable
Lifting the carriage and lock at the same height, strain the safety cable and then
release a little, and then tighten the cable nuts. Make sure the safety device can always
be worked properly.
Oil return port
Oil output port
Release valve
Release valve handle
Check valve
Relief valve
throttle
valve
Fig. 54
Cable nut
Fig. 53