O. Tighten all the hydraulic fittings, and fill the reservoir with hydraulic oil.
Note: In consideration of Hydraulic Power Unit’s durability and keep the equipment
running in the perfect condition, please use Hydraulic Oil 46#.
P. Install electrical system
Connect the power source on the data plate of power unit.
Note: 1. Install the limit switch well.
2. For the safety of operators, the power wiring must contact the floor well.
3.
Pay attention to the direction of rotations when using three phase motors.
Single phase motor
(See Fig. 40).
1. Connecting the two power supply wires (active wire
L
and neutral wire
N
) to
terminals of AC contactor marked L1, L2 respectively.
2. Connecting the two motor wires to terminals of AC contactor marked
T1, T2
.
3. Connecting
A2
to
L2
of AC contactor.
4. Terminal
4#
of control button is connected with terminals
A1
of AC contactor,
Terminal
3#
of control button is connected with terminals
L1
of AC contactor.
Fig. 40
AC contactor
Single phase
Control button
Button switch
P
ow
er
S
up
ply
Summary of Contents for OHX-10
Page 1: ...TWO POST LIFT Model OHX 10 OHX 10H Original...
Page 5: ...3 Arm Swings View Car in Fig 3...
Page 6: ...4 Swing and extending the arms to the lifting point of vehicle Fig 4...
Page 19: ...17 I Lift the carriages up and make them be locked at the same level See Fig 26 Fig 26...
Page 25: ...23 M Install safety cable See Fig 32 Fig 32 Wearing wire cable A side B side 25 25 86 7...
Page 34: ...32 IV EXPLODED VIEW OHX 10 Fig 46...
Page 35: ...33 OHX 10H Fig 47...
Page 41: ...39 5 Power unit 071101 explosive view single phase 220V 60HZ Fig 52...