16
I. Installing the limit switch control bar and limit switch
(See Fig. 25).
Limit switch
connected
with cable
Fig. 25
Limit switch cable wiring
Connect the brown wire
to the terminal 12# on
limit switch and terminal
4# on control button.
Connect the blue wire
to terminal 11# on
limit switch and
terminal A1 on AC
contactor of power unit
Adjust drive rod of limit
switch
Connect the yellow and
green wire to the earth
wire terminal on limit
switch and the earth wire
terminal of power unit.
68
34
33
29
34
35
Loosen screw of drive
rod for adjustment
Summary of Contents for OHX-10
Page 1: ...TWO POST LIFT Model OHX 10 OHX 10H Original...
Page 5: ...3 Arm Swings View Car in Fig 3...
Page 6: ...4 Swing and extending the arms to the lifting point of vehicle Fig 4...
Page 19: ...17 I Lift the carriages up and make them be locked at the same level See Fig 26 Fig 26...
Page 25: ...23 M Install safety cable See Fig 32 Fig 32 Wearing wire cable A side B side 25 25 86 7...
Page 34: ...32 IV EXPLODED VIEW OHX 10 Fig 46...
Page 35: ...33 OHX 10H Fig 47...
Page 41: ...39 5 Power unit 071101 explosive view single phase 220V 60HZ Fig 52...