background image

33 

Communication Menu

 

Device ID 

Setting Items 

Explanation 

1-255 

To set the ID number for machine 

Factory Setting 

 

Baud rate

 

Setting Items 

Explanation 

9600 

The Baud Ratio of Communication Port is 

set to be 9600 bps 

19200 

The Baud Ratio of Communication Port is 

set to be 19200 bps 

38400 

The Baud Ratio of Communication Port is 

set to be 38400 bps 

Factory Setting 

38400 

Note: The value must be set consistent to the communication port of the administration 

PC. Otherwise, no communication can be made. 

 

Port No

 

Setting Items 

Explanation 

1—9999 

To set the software port of the TCP/IP 

communication of the device 

Factory Setting 

5005 

Note:  The  port  must  be  consistent  to  port  number  of  the  software.  Otherwise  no 

communication can be made. 

 

 

Summary of Contents for AMG-I30B Series

Page 1: ...USERS MANUAL Proximity Time Attendance System Model AMG I30B Series...

Page 2: ...r time management products because we are committed to your satisfaction Every one of our products comes with a 1 year manufacturer s warranty and 30 free days of unlimited support That means a reduce...

Page 3: ......

Page 4: ...ATTENTION Please read the user s manual before operating your AMG I 30B Device Follow instructions on care and use to ensure and prolong the life of your device...

Page 5: ...ncluded in the Package I 30B Proximity Time clock Device Power Adapter USB or Serial RS232 cable Wiegand cable Wall mount and screws AMG Time Attendance Software If purchased as a package Hardware Man...

Page 6: ...2 Device External Diagram Front View Back View...

Page 7: ...ancel the current operation MENU Access the menu management OK Select the current item or set the current parameters Power ON OFF Scroll up the menu or decrease the numerical value Scroll down the men...

Page 8: ...4...

Page 9: ...e wall 4 5 feet above the ground 2 On the back of the device there are four grooves used to hang the device onto the mounting plate Align the four grooves on the Device with the four hooks on the moun...

Page 10: ...6 Configuring Communication mode...

Page 11: ...different types of communication modes when connecting to a computer with AMG software installed Ethernet TCP IP computer network Serial RS232 cable USB cable USB Flash disk data transfer RS485 Ether...

Page 12: ...nistrator for co IP Address Default Gateway and subnet mask configuration 4 Use or key to set Ethernet to Yes and RS communication to No 5 Insert LAN cables into the RJ 45 port on the RS 232 Communica...

Page 13: ...d 40 feet If the connection will be over a distance greater than 40 feet please use RS485 or Ethernet communication mode 1 Press Menu Key Setup Communication Set Device ID Baud Rate press ESC and pres...

Page 14: ...nd of cable should mounted to RJ 45 header and the other end is bare wire Connect the 7th and 8th pin respectively on 485 and 485 on the converter refer to appendix for more details 5 Connect the RS48...

Page 15: ...d analyzed by the AMG Attendance Software 2 All proximity card or PIN enrolled in device can be downloaded to the USB flash disk which later can be uploaded to a different AMG I 30B device Downloading...

Page 16: ...ve into the USB port of device 2 Press MENU Enroll USB Download AllEnrollDown 3 Press OK and start downloading the enrollment data 4 To upload enrollment data to a different device Plug the flash disk...

Page 17: ...rom employee with ID number 00001 If you press OK the password of Employee ID 00001 stored in device will be overwritten by New enrollment from USB flash disk This process will be repeated device fini...

Page 18: ...ll attendance data stored in terminal AGL_001 txt SLog Download Management Records Download the latest management data since the last download Poll SLG_001 txt All SLog Download All Management Records...

Page 19: ...evice ID Baud Rate press ESC and press OK to save changes 2 Connect the USB cable with one end connected to USB port of the PC and the other end to USB port in terminal 3 Power cycle device USB Cable...

Page 20: ...General Manager Super Administrator handles device management and configuration as well enrolling employees and other administrator full access on the other hand General Manager limited to handle emp...

Page 21: ...vice The range of ID number is 1 65535 The ID number is unique and cannot be repeated or reassigned at any later date 4 Wave proximity card to the proximity sensor area of the device After acquiring t...

Page 22: ...oll Manager Gen Manager Please refer to the step above to enroll Proximity cards Pin Note You must set the Super Administrator before you can set the General Manager Only Super Admin will be able to a...

Page 23: ...mber that is distributed to each employee in the device The range of ID number is 1 65535 The ID number is unique and cannot be repeated or reassigned at a later date A single employee single ID numbe...

Page 24: ...device will display ID number Press OK Note The ID number ranges from 1 65535 The devices will automatically assign the first unregistered ID number as the registration number You may use the numeric...

Page 25: ...st their proximity card 1 Press Menu key Enroll User Password press OK 2 Press ESC 3 You will need to enter the desired existing employee ID number enrolled in device and press OK Note if the ID numbe...

Page 26: ...cal keypad to input the password and then press OK you will be required to enter the 4 digits PIN twice as shown below Press OK to save 5 Press OK to confirm the new card and press OK to assign PIN to...

Page 27: ...g records security and downloading records to USB disk 2 Setup Allows Administrator to change device s configurations such as Date Time Communication and other device s operation settings 3 System Inf...

Page 28: ...l Menu Manager Super Admin Gen Manager Level Setting 1 1 Level 1 N Level Delete Glog View Slog View All GLog GLog Upload Enroll AllEnrollDown USB Download SLog All SLog AllLogDelete Enroll User Card P...

Page 29: ...fy Log Setup Time FMT Voice Out Lock Ctrl Shutdown Key LCD Contrast Autoshutdown Mode Daylight set Wiegand Out Bell Delay Managers Language Time Password IP address Subnet Mask Default Gateway Etherne...

Page 30: ...lish GEM Interface displayed in German FREN Interface displayed in French SPAN Interface displayed in Spanish KOR Interface displayed in Korean TCHN Interface displayed in Traditional Chinese SCHN Int...

Page 31: ...mpt The device will prompt 2 beeps for successful validation and one beep for failed verification Factory Setting Yes Lock Ctrl Setting Items Explanation Yes When confirmed the control signal of the e...

Page 32: ...device will terminate the auto shut down process Factory Setting No Wiegand Out Setting Items Explanation WG26 Sets Wiegand 26 bit protocol interface WG34 Sets Wiegand 34 bit protocol interface Facto...

Page 33: ...the month of daylight savings start 1 12 Sunday Set the Sunday of daylight savings start 0 4 Time H Set the daylight savings start time 0 23 Factory Setting Month 3 Sunday 4 Time H 2 c End set Setting...

Page 34: ...me function by setting DST Enable value to Yes Select Start set for setting month which Sunday and also hour of daylight savings time start Select End set for setting month which Sunday and also hour...

Page 35: ...sub menu as follows There are three level 3 submenus in Log Setup SLog Warn GLog Warn and Re Verify 1 SLog Warning Setting Items Explanation No The device will not alert you when the records are reac...

Page 36: ...ote Users are informed by message and voice prompt that the attendance record storage space is about to be full Once alert is given please download the records as soon as possible If the device exceed...

Page 37: ...to be 19200 bps 38400 The Baud Ratio of Communication Port is set to be 38400 bps Factory Setting 38400 Note The value must be set consistent to the communication port of the administration PC Otherw...

Page 38: ...4 Note The IP address in the LAN is unique Subnet Mask Setting Items Explanation 255 255 255 0 To set the subnet mask of the LAN when using TCP IP communication Factory Setting 255 255 255 0 Note Subn...

Page 39: ...Communication Switch Factory Setting Yes Note If the machine has TCP IP Ethernet function it is defaulted to be OFF Otherwise it is set to be ON Ethernet Setting Items Explanation Yes To set the switc...

Page 40: ...36...

Page 41: ...37 APPENDIX...

Page 42: ...m 3 and newer RAM 512 Mb Free hard disk space 40 GB and more depending on your database size Operating System requirements compatibility Operating System Windows XP Vista 7 Server 2003 Server 2008 R2...

Page 43: ...500 Logs Capacity 50 000 RS232 RS485 Yes Ethernet Yes USB Flash Disk Yes USB Cable Yes Voice Message Audio Battery Backup Yes Communication Baud Rate 9600 19200 38400 57600 115200 Suitable Card EM 125...

Page 44: ...initially configuring the device This prevents others from changing or tampering with their data and enhances your data s security Setting Gen Manager The Gen Manager has the authority to register a c...

Page 45: ...mats are supported YY MM DD MM DD YY and DD MM YY LCD Contrast If the display is too light or too dark you may adjust the screen Range 0 63 The lower the value the darker the display will be Conversel...

Page 46: ...ill be prompted to select one of the eight available actions Device ID Default Value 1 Baud Rate The default baud rate is 38400 The baud rate refers to the speed of the data The higher the value and t...

Page 47: ...S232 It is suggested that the communication distance should not exceed 1200 meters Ethernet If set to Yes the computer can operate a TCP IP connection with the device Otherwise the connection will not...

Page 48: ...anagement software If lunch break restriction is enabled and user punches when the lunch break duration is not over yet then on the device screen will be displayed Punch denied because of short lunch...

Page 49: ...d 8 Pin external extension interface 2 RJ45 Interface The interface provides RS485 and Ethernet communication functions For different devices some of them provide two RJ45 Interfaces and thus the defi...

Page 50: ...e connect the 7th pin of base end to and the 8th pin to Insert the header of the RS485 connection wire to the RJ45 interface on the attendance device RJ45 PIN Color of Corresponding Network Wire 1 Ora...

Page 51: ...47 3 8 Pin Wiegand Extension Interface Expand eight slot port to supply simple attendance and standard Wiegand port PIN Definition 1 DO OUT 2 D1 OUT 3 RELAY0 4 RELAY1 5 L0CK0 6 LOCK1 7 GND 8 DC5V...

Page 52: ...48...

Page 53: ...rnia all of our AMG technical support are ready to assist you for any question regarding installation setup configuration and troubleshooting Fee and charges only applies after 30 days from system reg...

Page 54: ...2 Thank you again for your purchase of the AMG Attendance System...

Reviews: