Revised 09 /2005
E-mail: [email protected]; [email protected] ; website: www.amfreece.com
Phones: +420 582 309 146 (Service), +420 582 309 286 (Spare Parts) ; Fax: +420 582 360 606
1- 5 1
84-55
CONTROLS & PROGRAM DESCRIPTION
Screen 4.2.d19 displays two parameters.
a)
End BT Drv Spd:
This is the speed of DC motor set during back tack operation at the
cycle end.
b)
End BT Hd Spd:
This is the speed parameter set for the sewing head motor when the jig
is moving for back tack operation at the end of cycle end. Press key
F1
to enter into next
Screen 4.2.d20.
End Feed out – No
End Rev Feed - No
Screen 4.2.d20
There are certain jigs for which it is required to move the jig forward or backward after the comple-
tion of cycle. To have this feature included in our program it is necessary to select End Feed out –
Yes. If this parameter is selected ‘No’ then other parameter End Rev Feed has no significance. When
the other parameter End Rev Feed is selected ‘Yes’ then after the completion of cycle DC motor will
rotate the jig in reverse otherwise in forward direction and the sewing head motor stands still.
Press key
F1
to enter into Screen 4.2.d21.
End Feed out
Time – 0.0s
Screen 4.2.d21
This parameter defines the time for how long DC motor should run for the feed out parameter de-
fined in Screen 4.2.d20. Press key
F1
to enter into Screen 4.2.d22.
Jig Flap Use - Yes
Screen 4.2.d22
To keep the jig flap up at time of cycle start and cycle end this parameter must be set to ‘Yes’. If this
parameter is set ‘No’, then jig will not be ejected automatically after the cycle end. Press key
F1
to
enter Screen 4.2.d23.
Photocell Retry
Quantity - 00
Screen 4.2.d23