Revised 09/2005
E-mail: [email protected]; [email protected] ; website: www.amfreece.com
Phones: +420 582 309 146 (Service), +420 582 309 286 (Spare Parts) ; Fax: +420 582 360 606
1- 3 4
84-55
CONTROLS & PROGRAM DESCRIPTION
Safety Cover
Bypass-N X12 - Off
Screen 4.1.a.11
There is an Acrylic sheet cover for the safety of operator around the needle area. A micro switch is
attached with this cover. When this cover is opened or closed the display changes from
X12 - On
to
X12 - Off
accordingly. Pressing key
F1
will enter back to Screen 4.1 and pressing key
F2
will
enter into the previous screen 4.1.a.10.
5.2.2 OUTPUT TESTING MODE
Screen 4.1 also shows output testing mode. Pressing key
F4
enters into the first screen of this mode
i.e. Screen 4.1.b.1. This screen shows Knife solenoid valve output. Press key
F6
,
Y00 – Offf
will
F1
F2
F3
F4
F5
F6
NEXT
PREV
CLR
ENT
Knife S/V
Y00 – On
start flashing, then pressing key
F4
once, will change the output status from
Y00 – Offf
to
Y00 –
On
and then pressing key
F6
will energize pneumatic solenoid for knife up/down operation (Press-
ing the key
F4
again while the display is flashing will toggle the
On/Off
status) and the display
will stop flashing. Pressing key
F1
will enter into the next Screen 4.b.1.2 and pressing key
F2
will enter into the previous screen 4.1.
Screen 4.1.b.1