Revised 09 /2005
E-mail: [email protected]; [email protected] ; website: www.amfreece.com
Phones: +420 582 309 146 (Service), +420 582 309 286 (Spare Parts) ; Fax: +420 582 360 606
1- 4 1
84-55
CONTROLS & PROGRAM DESCRIPTION
5.2.3 NEEDLE TEST
Pressing key
F1
in Screen 4.1 will enter into Screen 4.1.1.
Position test – F3
Restore Pgm – F4
Screen 4.1.1
Screen 4.1.1 displays two modes i.e. Position test and Restore Program. Pressing key
F3
will enter
into Screen 4.1.2.
Needle Position –
Up X01,X00 - 01
Screen 4.1.2
In Screen 4.1.2, pressing key
F6
will result in flashing of Up or Dn characters on the display. Press
key
F4
once to change from Up to Dn or vice versa while the display is flashing. Then press key
F6
again. This will make the sewing motor run till needle up or needle down position is acquired by
the machine. On the display, X01,X00 – 01 will appear when machine is at needle up position and
X01,X00 – 10 will appear when machine is at needle down position. Pressing key
F1
will enter into
Screen 4.2.
In Screen 4.1.1, when key
F4
is pressed, it will enter into Screen 4.1.1.c1. This screen is used to
select a default program. This default program is nothing but a reset program, where all the
Yes
conditions in the program are set to
No
and all the integer value parameters are set to zero. To select
a program that is intended to be reset, press key
F6
the program number
Pgm - …
starts blinking.
Then press key
F4
to increment the number or press key
F5
to clear the
Pgm
number and press
key
F6
to store the value. Press key
F3
for
Yes
es
and press key
F1
to enter into Screen 4.1.1.c2 or
press key
F2
to return to Screen 4.2.
Restore Pgm – 4
F3 - Yes
Screen 4.1.1.c1