C-2
M370185-01
Speci
fications
Electrical Specifications for XTR 850 Watt
Table C-1
XTR 850 Watt Electrical Specifications for 6 V to 600 V Models
Models
6-110
8-100
12-70
20-42
33-25
40-21
60-14
80-10.5
100-8.5
150-5.6
300-2.8
600-1.4
Output Ratings:
Output Voltage
1
Output Current
2
Output Power
3
6 V
110 A
670 W
8 V
100 A
810 W
12 V
70 A
850 W
20 V
42 A
850 W
33 V
25 A
835 W
40 V
21 A
850 W
60 V
14 A
850 W
80 V
10.5 A
850 W
100 V
8.5 A
860 W
150 V
5.6 A
850 W
300 V
2.8 A
850 W
600 V
1.4 A
850 W
Line Regulation:
Voltage
4
(0.005% of rated
output v2 mV)
Current
5
(0.01% of rated
output c2 mA)
2.3 mV
13 mA
2.4 mV
12 mA
2.6 mV
9 mA
3.0 mV
6.2 mA
3.7 mV
4.5 mA
4 mV
4.1 mA
5 mV
3.4 mA
6 mV
3.1 mA
7 mV
2.9 mA
9.5 mV
2.6 mA
17 mV
2.3 mA
32 mV
2.1 mA
Load Regulation
Voltage
6
(0.005% of rated
output v 2 mV)
Current
7
(0.02% of rated
output c5 mA
2.3 mV
27 mA
2.4 mV
25 mA
2.6 mV
19 mA
3.0 mV
13.4 mA
3.7 mV
10 mA
4 mV
9.2 mA
5 mV
7.8 mA
6 mV
7.1 mA
7 mV
6.7 mA
9.5 mV
6.1 mA
17 mV
5.6 mA
32 mV
5.3 mA
Output Ripple (rms, 300 kHz):
Voltage
Current
8
8 mV
200 mA
8 mV
180 mA
8 mV
120 mA
8 mV
75 mA
8 mV
60 mA
8 mV
45 mA
8 mV
35 mA
8 mV
25 mA
8 mV
20 mA
10 mV
16 mA
25 mV
10 mA
50 mV
6 mA
Output Noise (p-p, 20 MHz):
Voltage
50 mV
50 mV
50 mV
50 mV
50 mV
50 mV
50 mV
80 mV
80 mV
100 mV
150 mV
250 mV
Maximum Recommended Remote
Sense Line Drop Compensation per
Line
9
1 V
1 V
1 V
1.5 V
2 V
2 V
3 V
5 V
5 V
5 V
5 V
5 V
Up-prog. Response Time,
0~Vmax
10
60 ms
60 ms
60 ms
60 ms
60 ms
60 ms
60 ms
100 ms
100 ms
100 ms
150 ms
250 ms
Down-prog. Response Time: Full
Load
50 ms
50 ms
50 ms
50 ms
50 ms
50 ms
50 ms
80 ms
100 ms
150 ms
150 ms
250 ms
Down-prog. Response Time: No
Load
300 ms
400 ms
500 ms
600 ms
700 ms
800 ms
900 ms
1000 ms
1200 ms
1800 ms
2200 ms
3500 ms
Over-Voltage Trip Point
0.5–7.5 V
0.5–10 V
1–15 V
1–24 V
2–39 V
2–44 V
3–66 V
3–95 V
3–125 V
3–180 V
5–330 V
5–660 V
Summary of Contents for Soresen XTR 100-8.5
Page 2: ......
Page 16: ...xiv ...
Page 28: ...1 8 ...
Page 50: ...Local Operation 3 8 M370185 01 Figure 3 3 Front Panel Menu System ...
Page 93: ...Using Multiple Power Supplies M370185 01 3 51 3 ...
Page 94: ...Local Operation 3 52 M370185 01 ...
Page 128: ...Analog Programming APG and Isolated Analog Programming ISOL 4 34 M370185 01 ...
Page 198: ...Remote Operation 5 70 M370185 01 ...
Page 261: ...SCPI Command Tree M370185 01 A 35 A ...
Page 262: ...A 36 ...
Page 279: ...Index M370185 01 IX 3 described 3 7 3 36 number available 3 36 stored values 3 36 ...
Page 280: ...IX 4 ...