SCPI Error/Event Queue
M370185-01
5-51
5
Examples:
SYST:ERR?
SYST:ERR:EVENT?
Responses might be:
-102, "syntax error;”
0, "No Error;"
Querying For the Error Code Only
It is possible to query for only the error code. When querying the error
code only the response will be the numeric error code only, no additional
description will be given. The error queried will be removed from the
queue.
Command:
[:]SYSTem:ERRor:CODE[:EVENt]?
Example:
:SYST:ERR:CODE?
SYST:ERR:CODE:EVENT?
Responses might be:
-102
0
Querying For the Number of Errors in the Queue
To query the device for the number of errors currently stored in the error
queue you should use the following command.
Command:
[:]SYSTem:ERRor:COUNt?
Example:
:SYST:ERR:COUN?
Response might be:
3
Summary of Contents for Soresen XTR 100-8.5
Page 2: ......
Page 16: ...xiv ...
Page 28: ...1 8 ...
Page 50: ...Local Operation 3 8 M370185 01 Figure 3 3 Front Panel Menu System ...
Page 93: ...Using Multiple Power Supplies M370185 01 3 51 3 ...
Page 94: ...Local Operation 3 52 M370185 01 ...
Page 128: ...Analog Programming APG and Isolated Analog Programming ISOL 4 34 M370185 01 ...
Page 198: ...Remote Operation 5 70 M370185 01 ...
Page 261: ...SCPI Command Tree M370185 01 A 35 A ...
Page 262: ...A 36 ...
Page 279: ...Index M370185 01 IX 3 described 3 7 3 36 number available 3 36 stored values 3 36 ...
Page 280: ...IX 4 ...