APPENDIX A
SCPI Command Reference
A-4
M370430-01 Rev F
Using SCPI Commands
This Manual shows SCPI commands in the following format:
CALibration:CURRent:LEVel {<current>|MIN|MAX}
The command is expressed as a mixture of upper- and lowercase letters.
The uppercase letters suggest how the command can be abbreviated into
a short form. SCPI commands can be sent in long or short forms. The
short form is better for data entry. The long form is better for readability.
Command strings are not case sensitive:
CURR, Curr,
and
curr
are all
acceptable abbreviations for
CURRent
. As for the long form,
CURRENT
,
Current
, and
current
are all acceptable. It is not possible to write for
example,
CALibrat: CURR: LEV
because the extra first node does not
explicitly match the short or long form of the calibration node.
The command strings include punctuation. While some punctuation is
sent with the string, other markings are used to identify different
elements of the command syntax and are not sent with the string.
The following punctuation is sent with the command string:
Colons
(:) separate command keywords from lower-level
keywords. For example,
CAL : CURR: STAT.
Blank spaces
separate command keywords from parameter values.
For example,
CURR 0.1.
Commas
separate parameters from each other when more than one
parameter is sent in the same string. For example,
CAL: STAT
OFF,”1234.”
Semicolons
(;) separate multiple commands from the same
subsystem. This allows for greater efficiency.
For example: CAL:CURR:LEV MIN;VOLT:LEV MIN
is the same as typing:
CAL:CURR:LEV MIN
CAL: VOLT: LEV MIN
Colons and semicolons
can be used together to link commands
from different subsystems. For example:
CAL:CURR:LEV MIN;:MEAS:CURR?
The short form is made up of 3 or 4 letters. There can only be a
absolute short or long form. For example, it is not possible to write
CALibrat: CURR: LEV because the extra the first node does not
match explicitly the short or long form of the calibration node.
Summary of Contents for Sorensen XG 100-15
Page 2: ......
Page 93: ...Local Operation M370430 01 Rev F 3 47 3 Figure 3 5 Series Operation ...
Page 99: ...Local Operation M370430 01 Rev F 3 53 3 ...
Page 100: ...Local Operation 3 54 M370430 01 Rev F ...
Page 220: ...Communications Options 6 14 M370430 01 Rev F ...
Page 244: ...Communications Options 6 38 M370430 01 Rev F ...
Page 252: ...Communications Options 6 46 M370430 01 Rev F ...
Page 292: ......
Page 329: ...M370430 01 Rev F A 37 A APPENDIX A SCPI Command Reference ...
Page 330: ......
Page 368: ...APPENDIX D Rack Mount Options and Installation Instructions D 12 M370430 01 Rev F ...
Page 369: ...APPENDIX D Rack Mount Options and Installation Instructions M370430 01 Rev F D 13 ...
Page 370: ......
Page 395: ...Rack Mount Options and Installation Instructions M370430 01 Rev F E 25 ...
Page 396: ......
Page 399: ......