STRATOS WITH ENCLOSURE:
Install Manual
25MAR2022 | 630-00147 C
15
INSTALLATION
STRATOS WITH ENCLOSURE: SECTION 4
3.
Verify that hot, neutral and ground conductors
where the temporary power cord will connect are
correct. Incorrect wiring or lack of ground could
cause unit malfunction.
WARNING
!
Remove 4X screws on junction box cover
inside the tower. Retrieve 4' temporary power
cord from the parts kit. Route stripped end of
wire into the junction box. See Figure 4-3.
Figure
4-3
Make the following connections:
• Black to Black (L1 Hot)
• White to White (L2 Neutral)
• Green to Green (Ground)
If a battery backup is included, there will also be
two (2) brown wires in the junction box. The two (2)
brown wires get tied to each other. See Figure 4-4.
Figure 4-4
Brown wires are the disconnect for the battery
backup output. As long as brown wires are tied
together, the inverter will not be disconnected
during service.
WARNING
!
4. Connect a temporary cord to a grounded 20A
extension cord and route down through the
back of the center wire channel to the bottom
of the lift and out to a temporary 120V AC
outlet. See Figure 4-5.
Junction
box
Back
brace of
tower
Wire
channel
Figure 4-5
5. Once power is established and the VPL comes
online, the indicator LED's on the control
board will flash an alarm code to indicate that
the installation is incomplete.