background image

2

You can be killed or seriously injured if you don't

immediately follow instructions.

You can be killed or seriously injured if you don't

follow instructions.

All safety messages will tell you what the potential hazard is, tell you how to reduce the chance of injury, and tell you

what can happen if the instructions are not followed.

Your safety and the safety of others are very important.

We have provided many important safety messages in this manual and on your appliance. Always read and obey all

safety messages.

This is the safety alert symbol.
This symbol alerts you to potential hazards that can kill or hurt you and others.
All safety messages will follow the safety alert symbol and either the word “DANGER” or

“WARNING.” These words mean:

Important Instructions

·

Do not use this appliance if any part has been under water. Immediately call a qualified service 

technician. Water heaters subjected to flood conditions or anytime the gas controls, main burner or pilot have 

been submerged in water require replacement of the entire water heater.

·

Hydrogen gas can be produced in a hot water system that has not been used for a long period of time (generally

two weeks or more). Hydrogen gas is extremely flammable and can ignite when exposed to a spark or flame. 

To prevent the possibility of injury under these conditions, we recommend the hot water faucet be opened for 

several minutes at the kitchen sink before using any electrical appliance which is connected to the hot water 

system. If hydrogen is present, there will probably be an unusual sound such as air escaping through the faucet

as water begins to flow. Do not smoke or have any open flame near the faucet at the time it is open.

The California Safe Drinking Water and Toxic Enforcement Act requires the Governor of California to publish a list of

substances known to the State of California to cause cancer, birth defects, or other reproductive harm, and requires

businesses to warn of potential exposure to such substances.

Warning:

  This product contains a chemical known to the State of California to cause cancer, birth defects, or other

reproductive harm.
This appliance can cause low-level exposure to some of the substances listed, including formaldehyde, carbon monxide,

and soot.

Table of Contents

Water Heater Safety...........................................................

Installing Your Gas Water Heater............................

 

Unpacking the Water Heater..................................

Location Requirements...........................................

Vent Cap Termination............................................

 

Gas Supply..............................................................

Combustion Air Supply and Ventilation..................

Vent Pipe System....................................................

Water System Piping..............................................

Special Applications..........................................

Installation Checklist...............................................

Operating Your Water Heater............................................

Lighting Instructions............................................................

Operational Conditions...........................................

Maintenance of Your Water Heater........................

Troubleshooting Chart........................................................

Repair Parts Illustration...............................................

PAGE

1-2

3-16

3

4-5

5-6

7-8

9

9-11

12-14

15

16

17-18

17-18

20

21-24

25-26

27-28

Summary of Contents for 6510238

Page 1: ...inity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch do not use any phone in your building Immediately call your gas su...

Page 2: ...possibility of injury under these conditions we recommend the hot water faucet be opened for several minutes at the kitchen sink before using any electrical appliance which is connected to the hot wat...

Page 3: ...ions outlined in this manual If you lack the necessary skills required to properly install this water heater or you have difficulty following the instructions you should not proceed but have a qualifi...

Page 4: ...p Drain Drain Pan NOTE In the State of California the water heater must be braced anchored or strapped to avoid moving during an earthquake Contact local utilities for code requirements in your area o...

Page 5: ...paces i e attics basements etc may require insulation of the water piping and drain piping to protect against freezing The drain and controls must be easily accessible for operation and service Mainta...

Page 6: ...Figure 5 Protective Louvered Wall or Fence 3 feet Min Figure 4 Vent Cap Termination Locations A 12 in 30 cm min clearance above grade veranda porch deck balcony or maximum anticipated snow level B 9...

Page 7: ...e of local and state codes the National Fuel Gas Code ANSI Z223 1 NFPA 54 latest edition Tables 1 and 2 on page 8 are provided as a sizing reference for commonly used gas pipe materials Consult the Na...

Page 8: ...00 125 150 TABLE 2 LP GAS CAPACITY TABLE Maximum capacity of pipe in thousands of BTU per hour of undiluted liquefied petroleum gases at 11 inches water column pressure Based on a Pressure Drop of 0 5...

Page 9: ...n of electrical wiring pipes or wall studs before cutting NOTE Installations requiring an A dimension vertical height greater than what is shown as standard in the table will require the use of a vert...

Page 10: ...Wall Plate Screws Sealant 3 Telescoping Pipe 5 Telescoping Pipe Outer Wall Plate Inner Wall Plate Screws Sealant Outer Wall Plate HOT Screws Vent Cap Screws Sealant Slope down 1 4 per foot Optional V...

Page 11: ...sheet metal screws 90 apart and seal the joint with sealant Then attach the 5 section in the same manor Drill 1 8 pilot holes for the screws Continue until the full length is assembled Put the telesc...

Page 12: ...temperature of the water by mixing cold and hot water and are readily available for use Contact a licensed plumber or the local plumbing authority 4 If installing the water heater in a closed water sy...

Page 13: ...T add any chemicals to the system piping which will contaminate the potable water supply Closed System Thermal Expansion Periodic discharge of the temperature and pressure relief valve may be due to t...

Page 14: ...n Important Only a new temperature and pressure relief valve should be used with your water heater Do not use an old or existing valve as it may be damaged or not adequate for the working pressure of...

Page 15: ...to limit the risk of scald injury Pumps valves piping and fittings must be compatible with potable water A properly installed flow control valve is required to prevent thermosiphoning Thermosiphoning...

Page 16: ...ater solution or other approved means used to check all connections and fittings for possible gas leaks INSTALLATION CHECKLIST 16 Water System Piping Temperature and pressure relief valve properly ins...

Page 17: ...lowest setting 1 Remove the outer door 2 Turn the temperature dial counterclockwise to its lowest setting 3 Turn gas control knob clockwise to the OFF position 4 To clear any gas that may have accumul...

Page 18: ...ter repeat steps 4 7 Continue to hold the knob for about 1 minute after the pilot is lit Release the gas control knob and it will pop back up Pilot should remain lit If the pilot light goes out repeat...

Page 19: ...f the thermostat is set too high Important Adjusting the thermostat past the 120 F bar on the temperature dial will increase the risk of scald injury Hot water can produce first degree burns within 12...

Page 20: ...ed pipe sealant on threads and install new anode rod 6 Turn on water supply and open nearby hot water faucet to purge air from water system 7 Restart the water heater as directed under Operating Your...

Page 21: ...piping systems main burner and pilot burner Check the water heater for the following Obstructions damage or deterioration in the venting system Make sure the ventilation and combustion air supplies a...

Page 22: ...internal parts Figure 19 Screw 6 Places N O T W A H S T R E B O R I A C A V M R A W U T O H T H E R I SK OF Y R U J N I D L A C S R E T T O H W A T ER I S E S A E R C N N O I A C T U N I T R O L READ...

Page 23: ...r 6 See Replacing Manifold Assembly at the top of next column 23 Replacing the Manifold Assembly 1 Check the door gasket for damage or imbedded debris prior to installation 2 Insert the manifold assem...

Page 24: ...e igniter button by depressing front and rear holding tabs and lift Disconnect the thermocouple pilot tube and manifold tube L P models have left hand threads at the thermostat Figure 19 5 Refer to Ga...

Page 25: ...from the gas line 3 Check with gas utility company 4 Notify utility install dirt trap in gas line 5 Clean locate source and correct 6 Finger tighten then 1 4 turn with wrench 7 Replace thermocouple 8...

Page 26: ...r Flame Yellow Lazy 1 Insufficient secondary air 2 Low gas pressure 3 Flue clogged 4 Defective thermostat 5 Heater installed in a confined area 6 Burner flame yellow lazy 1 Insufficient secondary air...

Page 27: ...UPPER AIR BOX FIVE INCH ELBOW THREE INCH ELBOW INNER WALL PLATE 4 TO 3 REDUCER MANIFOLD DOOR GASKET THREE INCH TELESCOPING PIPE FIVE INCH TELESCOPING PIPE OUTER WALL PLATE VENT CAP ASSEMBLY FRESH AIR...

Page 28: ...lot burner and the thermostat must be ordered for the proper gas type 2005 American Water Heater Company All Rights Reserved Natural Gas Manifold Door Assembly L P Gas Manifold Door Assembly 30 17 28...