Page 25
200 Series 36V
15312
Power to Small Posts of Contactor
Use “V” setting on the meter.
Place the RED probe on the small stud of the contactor, with the orange wire, and the
BLACK probe to a good chassis ground such as the negative (-) post at the 350 amp
fuse.
Turn the ignition key to the “ON” position.
The meter should read at least 36 volts.
Meter Result > 36V
One (+) probe placement shown
(either small post with an orange
wire is acceptable)
(+) probe placement to
either small post with the
orange wire
(-) probe placement
to any good chassis ground
Contactor