SET EVENT TIMERS
Event Timers permits automatic callup of System Tours and/or
Alarm Monitor/Contact Tables. (See pages 4-5 and 4-26
respectively for System Tour and Monitor/Contact Table
programming.) Each one of the automatic callups is referred
to as an Event.
The EVENT TIMER menu is used to identify each Event and
to program each Event for automatic callups. A maximum of
35 Events are available for programming. Each Event can be
programmed for individual System Tour and Alarm
Monitor/Contact Table callups on different days of the week.
An Event Timer (“Event”) is created by entering a new time in
the first line. If the Event is a new time the word “NEW” is
displayed. If the Event already exists, either the word
“ENABLED” or “DISABLED” is displayed. If the timer is
cleared, the words “ILLEGAL TIME” are displayed.
1. Move the cursor to the time location under the menu title.
2. Enter the hours (for example, 07).
3. Press the ACK key.
4. Enter the minutes (for example, 11).
5. Press the ACK key. This moves the cursor to the EDIT
TIMER line item in the EVENT TIMER menu.
Note: A maximum of 35 Event Timers can be programmed.
If a time is entered for a 36th event, the message “EVENT
TABLE FULL” is displayed. An existing Event Timer
can be cleared to make room for a newly created table (see
CLEAR TIMER menu command, page 4-11).
EDIT TIMER
Place the cursor on the EDIT TIMER line and press the ACK
key to display the SET EVENT TIMERS menu. This menu is
used to program the entries for System Tours and Alarm
Monitor/Contact (ALM) callup.
This menu has four pages with eight monitors per page. See
page 4-3 for cursor movement instructions.
Note: The day of the week must be set properly for Events to
occur as desired. See page 4-4 to set day of the week.
System Tour callup
Each entry in this table identifies a System Tour that is called
at the specified Event time for the indicated monitor (MON) on
the indicated day of the week. The entries for a new Event
Timer are defaulted to 0, no System Tours called to monitors.
To program a System Tour for callup by an Event Timer:
1. Move the cursor to the desired day of week and MON
(monitor) position.
2. Enter the System Tour number to call to this monitor.
3. Press the ACK key.
Note: Entering 00 is a “no-action” command while 65 is a
“hold monitor at current camera” command.
4-10
1996R MENU PROGRAMMING
E V E N T T I M E R
0 7 : 11 D I S A B L E D
E D I T T I M E R
N E X T T I M E R
C L E A R T I M E R
E N A B L E T I M E R
C H A N G E T I M E R T O H H : M M
P R E V I O U S M E N U
S E T E V E N T T I M E R S
T I M E - 0 7 : 11
D AY O F W E E K
M O N
S
M
T
W
T
F
S
0 0 1
0 1
0 2
0 3
0 4
0 5
0 6
0 7
0 0 2
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0 3
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0 4
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0 5
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0 6
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0 7
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0 8
0 0
0 0
0 0
0 0
0 0
0 0
0 0
A L M
0
1
0
0
0
0
0
P R E V I O U S M E N U
S Y S T E M
1 S E T T I M E A N D D AT E
2 S E T S Y S T E M T O U R S
3 S E T S Y S T E M S A LV O S
4 S E T E V E N T T I M E R S
5 S E T A L A R M C O N TA C T S
6 M O N I T O R S TAT U S
R E T U R N M A I N