SET SYSTEM TOURS
A System Tour is a programmable sequence of cameras that
can be called to be displayed on the called monitor, or called
by Event Timers. The SET SYSTEM TOURS menu permits
programming of 64 System tours. The tour being programmed
is identified in the TOUR line of the menu. Each tour includes
64 entries. Each entry contains a camera number, dwell time,
preset, auxiliary, and connect next.
The Set System Tours menu has four pages, with 16 entries per
page. Refer to page 4-3 for menu paging instructions.
ENT (Entry) - Each of the 64 entries in a tour consists of a
camera number, dwell time, preset number, auxiliary number,
and a connect next designation (for salvos). Each tour entry is
unique and the same camera (with different dwell times,
presets, etc.) may be entered as many times as required.
CAM (Camera) - A camera number is associated with each
tour entry. If the CN field is an “S” or “T” the tour entry is
associated with a System Salvo or another System Tour, that is,
the CAM number is a System Salvo or System Tour number.
DWL (Dwell Time) - The dwell time is the length of time the
camera is displayed on the monitor before switching to the
next tour entry. The dwell time may be from 1 to 60 seconds;
an entry of 61 will “HOLD” the current camera displayed.
PRE (Preset) - If the camera is equipped with motorized
pan/tilt and lens with feedback potentiometers, preset scenes
may be defined (page 3-3). If presets have been defined, the
preset scene specified in this entry is called automatically
when the camera associated with that entry is displayed on the
monitor. If a preset is not desired, enter a zero in this field.
AUX (Auxiliary) - If the camera site is equipped with a
Receiver that has Auxiliary relays, an auxiliary can be
activated automatically during a tour. See the appropriate set-
up information in the associated Receiver manual. If no
auxiliary is desired, enter a zero in this field.
CN (Connect Next) - Connect Next selects the next camera in
the table for simultaneous callup to the next contiguous
monitor, thereby forming a “Scratch Pad” Salvo call. A salvo
simultaneously calls up a set of cameras to contiguous
monitors for the dwell time specified by the first camera entry.
A selection of Yes (“Y”), No (“N”), Salvo (“S”), or Tour (“T”)
can be chosen for Connect Next.
• If “Y” is selected, the Connect Next feature calls the next
tour entry to the next monitor; a Dwell Time cannot be
programmed for the next entry.
• If “N” is selected, the Connect Next feature is not initiated.
The next entry in the table is selected for the called monitor
after the specified dwell time.
• If “S” is selected, a pre-programmed System Salvo is called.
The System Salvo number is specified in the CAM entry.
• If “T” is selected, another System Tour is called. The
System Tour number is specified in the CAM entry.
The Tour within a Tour feature (the selection of “T”) links
the desired number of tours together. It is recommended that
the last entry in a tour be used to call the next desired tour.
Note: A tour cannot call itself.
PREVIOUS MENU - Returns to the SYSTEM menu.
4-5
1996R MENU PROGRAMMING
S E T S Y S T E M T O U R S
T O U R - 0 1
E N T
C A M
D W L
P R E
A U X
C N
0 1
0 0 0 1
0 2
0 1
1 O N
N
0 2
0 0 0 2
0 2
0 2
2 O N
N
0 3
0 0 0 3
0 2
0 3
3 O N
N
0 4
0 0 0 4
0 2
0 4
4 O N
N
0 5
0 0 0 5
0 2
0 5
1 O F F
N
0 6
0 0 0 6
0 2
0 6
2 O F F
N
0 7
0 0 0 7
0 2
0 7
3 O F F
N
0 8
0 0 0 8
0 2
0 8
0
N
.
.
6 4
0 0 6 4
0 2
0 1
1 O N
N
P R E V I O U S M E N U
S Y S T E M
1 S E T T I M E A N D D AT E
2 S E T S Y S T E M T O U R S
3 S E T S Y S T E M S A LV O S
4 S E T E V E N T T I M E R S
5 S E T A L A R M C O N TA C T S
6 M O N I T O R S TAT U S
R E T U R N M A I N