background image

American DJ

®

  -  www.americandj.com  - Vizi Spot LED PRO - Instruction Manual - Page 11

American DJ

®

  -  www.americandj.com  - Vizi Spot LED PRO - Instruction Manual - Page 12

should be made with a male and female XLR connector on either end 

of the cable. Also remember that DMX cable must be daisy chained 

and cannot be split.

 Vizi Spot LED PRO 

 

 

                       Set Up

Notice:

 Be sure to follow figures two and three when making your own 

cables. Do not use the ground lug on the XLR connector. Do not con-

nect the cable’s shield conductor to the ground lug or allow the shield 

conductor to come in contact with the XLR’s outer casing. Grounding 

the shield could cause a short circuit and erratic behavior.

DMX512 IN

3-PIN XLR

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

DMX512

DMX+,DMX-,COMMON

1

2

3

Termination reduces signal errors and

avoids  signal  transmission  problems

and interference. It is always advisable

to connect a DMX terminal, (Resistance

120 Ohm 1/4 W) between PIN 2 (DMX-)

and PIN 3 (DMX +) of the last fixture.

1

2

3

1

2

3

DMX +

DMX -

COMMON

DMX512 OUT

3-PIN XLR

Figure 2

Figure 3

1 Ground

1 Ground

XLR Male Socket

XLR Pin Configuration

3 Hot

2 Cold

2 Cold

3 Hot

XLR Female Socket

Pin 3 = Data True (positive)

Pin 2 = Data Compliment (negative)

Pin 1 = Ground

Special Note: Line Termination.

 

When longer runs of cable are 

used, you may need to use a terminator on the last unit to avoid erratic 

behavior. A terminator is a 90-120 ohm 1/4 watt resistor which is con-

nected between pins 2 and 3 of a male XLR connector (DATA + and 

DATA -). This unit is inserted in the female XLR connector of the last 

unit in your daisy chain to terminate the line. Using a cable terminator 

(ADJ part number Z-DMX/T) will decrease the possibilities of erratic 

behavior. 

DMX512 IN

3-PIN XLR

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

DMX512

DMX+,DMX-,COMMON

1

2

3

Termination reduces signal errors and

avoids  signal  transmission  problems

and interference. It is always advisable

to connect a DMX terminal, (Resistance

120 Ohm 1/4 W) between PIN 2 (DMX-)

and PIN 3 (DMX +) of the last fixture.

1

2

3

1

2

3

DMX +

DMX -

COMMON

DMX512 OUT

3-PIN XLR

Figure 4

Power Supply:

  The American DJ

®

 Vizi Spot LED PRO contains a 

automatic voltage switch, which will auto sense the voltage when it 

is plugged into the power source. With this switch there is no need 

to worry about the correct power voltage, this unit can be plugged in 

anywhere.

DMX-512:

 DMX is short for Digital Multiplex. This is a universal pro-

tocol used by most lighting and controller manufactures as a form of 

communication between intelligent fixtures and controllers. A DMX 

controller sends DMX data instructions from the controller to the fix-

ture. DMX data is sent as serial data that travels from fixture to fixture 

via the DATA “IN” and DATA “OUT” XLR terminals located on all DMX 

fixtures (most controllers only have a DATA “OUT” terminal). 

DMX Linking: 

DMX is a language allowing all makes and models 

of  different  manufactures  to  be  linked  together  and  operate  from  a 

single  controller,  as  long  as  all  fixtures  and  the  controller  are  DMX 

compliant.  To ensure proper DMX data transmission, when using 

several DMX fixtures try to use the shortest cable path possible. The 

order in which fixtures are connected in a DMX line does not influence 

the DMX addressing. For example; a fixture assigned a DMX address 

of 1 may be placed anywhere in a DMX line, at the beginning, at the 

end, or anywhere in the middle. Therefore, the first fixture controlled 

by the controller could be the last fixture in the chain. When a fixture 

is assigned a DMX address of 1, the DMX controller knows to send 

DATA assigned to address 1 to that unit, no matter where it is located 

in the DMX chain.

Data Cable (DMX Cable) Requirements (For DMX and Master/Slave 

Operation): 

The Vizi Spot LED PRO can be controlled via DMX-512 

protocol. The Vizi Spot LED PRO can be either a 12 or 14 channel DMX 

unit. The DMX address is set electronically using 

the controls on the side panel of the unit. Your 

unit and your DMX controller require a approved 

DMX-512 110 Ohm Data cable for data input and 

data output (Figure 1). We recommend Accu-Cable 

DMX cables. If you are making your own cables, be 

sure to use standard 110-120 Ohm shielded cable 

(This cable may be purchased at almost all pro-

fessional sound and lighting stores). Your cables 

 Vizi Spot LED PRO 

 

 

                    Set Up

Figure 1

Summary of Contents for Vizi Spot LED PRO

Page 1: ...3 Introduction 3 Customer Support 3 Safety Precautions 4 General Information 5 Features 5 Registration 5 Mounting 6 Controls and Functions 8 DMX Set Up 8 System Menu 14 Editing Program 33 Error Codes...

Page 2: ...lease Read and Understand This Manual Completely Before You Attempt To Install Or Operate This Unit To reduce the risk of electrical shock or fire do not expose this unit rain or moisture Do not spill...

Page 3: ...2 fps Switchable 540 to 630 Pan Movement 270 Tilt Movement Digital Display for Address and Function Setting Vizi Spot LED PRO Features The Vizi Spot LED PRO carries a three year 1095 days limited war...

Page 4: ...tom of the Vizi Spot LED PRO Tighten the quick lock fasteners fully clock wise Install the second Omega holder Pull the safety cable through the holes on the bottom of the base and over the truss ing...

Page 5: ...ord Inlet This cord is designed to match the electrical requirements of the unit Voltage may vary from venue to venue when connecting this unit to a power supply be sure to connect to a match ing powe...

Page 6: ...2 OUT 3 PIN XLR Figure 4 Power Supply The American DJ Vizi Spot LED PRO contains a automatic voltage switch which will auto sense the voltage when it is plugged into the power source With this switch...

Page 7: ...atus ALL Reset all motors and returns fixture to home SCAN Reset only motors for pan tilt COLR Reset only motors for colors GOBO Reset only motors for gobo and rotation 3 RESE OTHR Reset other motors...

Page 8: ...s the unit to the default settings FEED Pan Tilt feedback error correction on off FANS Select the fan running mode HIBE This feature will automatically shut down the lamp and stepping motors Please se...

Page 9: ...nit Tap the UP 4 or DOWN 5 butons until you reach function you wish to change When you reach the function you wish to change tap the ENTER button Again tap the UP or DOWN buttons to change the functio...

Page 10: ...isplayed press ENTER 3 Tap the UP button until COLR is displayed 4 Press ENTER to reset the color wheel motor or press MODE 4 Press MODE ESC to exit PLAY MAIN MENU RUN Run the unit in an Auto mode as...

Page 11: ...on you can display the total running time of the unit 1 Access the main menu 2 Tap the UP button until TIME is displayed press ENTER 3 Tap the UP button until LIFE is displayed press ENTER 4 Press MOD...

Page 12: ...to the main menu Now the display will change as per the 5th channel DMX value D ON With this function On the display will shut off after 2 minutes 1 Access the main menu 2 Tap the UP button until DIS...

Page 13: ...ain menu Vizi Spot LED PRO System Menu SPEC MAIN MENU RDMX With this function you are able to change the DMX address via any DMX controller This function is factory set to ON already 1 Access the main...

Page 14: ...make the unit auto matically shut down the lamp and stepping motors The default setting for this is 15 mins After 15 mins if the unit Vizi Spot LED PRO System Menu If you want the set the address to 4...

Page 15: ...2 0 V 9 9 etc 5 Press MODE ESC to exit ADJU Use this function is used to make sure all motors are aligned and to adjust any motors that are not 1 Access the main menu 2 Tap the UP button until SPEC is...

Page 16: ...program select On and press ENTER to confirm 5 Press MODE ESC to return to the main menu Vizi Spot LED PRO System Menu EDIT This menu item allows you to write a program into the memory EEPROM via the...

Page 17: ...1 Access the main menu 2 Tap the UP button until EDIT is displayed Press ENTER 3 The display will show SCXX the X again stands for the scene number For example SC01 is displayed it means you will be e...

Page 18: ...t other functions will work properly The fixture will attempt to operate normally until the errors can be corrected by a technician The errors in question will remain flashing in the display as a remi...

Page 19: ...18 to set the DMX address 6 For longer cable runs more than a 100 feet use a terminator on the last fixture 7 For help operating in DMX mode consult the manual included with your DMX controller Stand...

Page 20: ...menu 7 You may change the show or invert the pan and tilt functions in the system menu by following the directions on page 22 Master Slave Operation Sound Active or Auto Program This function will al...

Page 21: ...Vizi Spot LED PRO Instruction Manual Page 41 American DJ www americandj com Vizi Spot LED PRO Instruction Manual Page 42 Vizi Spot LED PRO 14 Channel Mode Channel Value Function 9 PRISM ROTATION INDEX...

Page 22: ...0 9 OPEN 10 19 ROTATING GOBO 1 20 29 ROTATING GOBO 2 30 39 ROTATING GOBO 3 40 49 ROTATING GOBO 4 50 59 ROTATING GOBO 5 60 69 ROTATING GOBO 6 70 79 ROTATING GOBO 7 80 95 ROTATING GOBO 1 SHAKE 96 111 R...

Page 23: ...INDEXING 128 189 FORWARD PRISM ROTATION FAST SLOW 190 193 NO ROTATION 194 255 BACKWARD PRISM ROTATION SLOW FAST 8 FOCUSING 0 255 CONTINUOUS ADJUSTMENT FAR NEAR 9 SHUTTER STROBE 0 31 LED OFF 32 63 LED...

Page 24: ...remove the individual gobo set up Gently push the gobo frame Not the wheel away from the gobo wheel you do not have to push gobo frame to far Figure 3 While you are pushing the gobo frame away from t...

Page 25: ...t American DJ www americandj com Vizi Spot LED PRO Instruction Manual Page 49 American DJ www americandj com Vizi Spot LED PRO Instruction Manual Page 50 Vizi Spot LED PRO Changing the Gobo Figure 1 F...