Operating Power:

There are two ways to supply power to this unit; battery power or AC 

power. 

• AC Power - To run the unit using AC power, plug the unit into a power 

source, and put the Load Switch into the ON position. When using AC 

power make sure the Battery Switch is in the OFF position. 
• Battery Power - To run the unit using Battery power, put the Load and 

Battery Switches in the ON position.

LED Display On/Off:

To set the LED display to turn off after 20 seconds, press the MODE 

button until “don” is displayed, press the UP button to display “doff”. 

Now  the  display  will  disappear  after  20s.  Press  any  button  to  turn 

the display on again. Be advised though that the display will turn off 

automatically after 20 seconds. 
To set the display press the MODE button until “dXX” is displayed. 

Use the UP or DOWN buttons to select either:

“don” = LED display on at all times.

“doFF” = LED display shuts off after 20 seconds.

LED Display Inversion:

Follow these instructions to flip the display 180° so that the display 

can be read upside down. 
1. Plug the fixture in and press the MODE button until “dXX” is dis-  

   played. “XX” represents either “on” or “oFF”.

2. Press the SET UP button until “Stnd” is displayed.

3. Press the UP or DOWN buttons to reverse the display 180°.

Operating Modes:

The Mega Go Flood Par has five operating modes:

•  Sound-Active mode - The unit will react to sound, chasing through  

 the built in programs.

•  Static Color Mode - There are 35 colors to choose from.

•  Auto Mode - There are 3 Auto Modes to choose from. 

•  RGB Mode - Choose one of the three colors to remain static or    

  adjust the intensity of each color to make your desired color. 

•  DMX control mode - This function will allow you to control each

  individual fixtures traits with a standard DMX 512 controller such as

ADJ Products, LLC  -  www.adj.com  - Mega Go Flood Par User Manual Page 10

ADJ Products, LLC  -  www.adj.com  - Mega Go Flood Par User Manual Page 9

cables. Do not use the ground lug on the XLR connector. Do not con-

nect the cable’s shield conductor to the ground lug or allow the shield 

conductor to come in contact with the XLR’s outer casing. Grounding 

the shield could cause a short circuit and erratic behavior.

 Mega Go Flood Par 

                                           Set Up

DMX512 IN

3-PIN XLR

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

DMX512

DMX+,DMX-,COMMON

1

2

3

Termination reduces signal errors and

avoids  signal  transmission  problems

and interference. It is always advisable

to connect a DMX terminal, (Resistance

120 Ohm 1/4 W) between PIN 2 (DMX-)

and PIN 3 (DMX +) of the last fixture.

1

2

3

1

2

3

DMX +

DMX -

COMMON

DMX512 OUT

3-PIN XLR

Figure 2

Figure 3

1 Ground

1 Ground

XLR Male Socket

XLR Pin Configuration

3 Hot

2 Cold

2 Cold

3 Hot

XLR Female Socket

Pin 3 = Data True (positive)

Pin 2 = Data Compliment (negative)

Pin 1 = Ground

Special Note: Line Termination.

 

When longer runs of cable are 

used, you may need to use a terminator on the last unit to avoid erratic 

behavior. A terminator is a 110-120 ohm 1/4 watt resistor which is con-

nected between pins 2 and 3 of a male XLR connector (DATA + and 

DATA -). This unit is inserted in the female XLR connector of the last 

unit in your daisy chain to terminate the line. Using a cable terminator 

(ADJ part number Z-DMX/T) will decrease the possibilities of erratic 

behavior. 

DMX512 IN

3-PIN XLR

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

DMX512

DMX+,DMX-,COMMON

1

2

3

Termination reduces signal errors and

avoids  signal  transmission  problems

and interference. It is always advisable

to connect a DMX terminal, (Resistance

120 Ohm 1/4 W) between PIN 2 (DMX-)

and PIN 3 (DMX +) of the last fixture.

1

2

3

1

2

3

DMX +

DMX -

COMMON

DMX512 OUT

3-PIN XLR

Figure 4

5-Pin XLR DMX Connectors.

 

Some manufactures use 5-pin DMX-

512 data cables for DATA transmission in place of 3-pin. 5-pin DMX  

fixtures may be implemented in a 3-pin DMX line. When inserting stan-

dard 5-pin data cables in to a 3-pin line a cable adaptor must be used, 

these adaptors are readily available at most electric stores. The chart 

below details a proper cable conversion.

Conductor

5-Pin XLR Male (In)

3-Pin XLR Female (Out)

Pin 1

Do Not Use

Do Not Use

Pin 3

Pin 2

Pin 1

Pin 3

Pin 2

Not Used

Not Used

Data True (+ signal)

Data Compliment (- signal)

Ground/Shield

3-Pin XLR to 5-Pin XLR Conversion

Summary of Contents for Mega Go Flood Par

Page 1: ...ever you wish without the restrictions of power The built in battery will keep charge for up to 4 5 hours full on from a full single charge This fixture can be used in a stand alone mode or connected...

Page 2: ...ee page 23 for cleaning details Heat The appliance should be situated away from heat sources such as radiators heat registers stoves or other appliances inclu ding amplifiers that produce heat The fix...

Page 3: ...ttery Should the electrolyte gel come into contact with the skin or eyes flush the area of contact immediately with fresh water and seek medical attention immediately 3 4 Do Not Expose the Battery to...

Page 4: ...le a fixture assigned a DMX address of 1 may be placed anywhere in a DMX line at the beginning at the end or anywhere in the middle When a fixture is assigned a DMX address of 1 the DMX controller kno...

Page 5: ...nect the cable s shield conductor to the ground lug or allow the shield conductor to come in contact with the XLR s outer casing Grounding the shield could cause a short circuit and erratic behavior...

Page 6: ...speed or F XX color fade speed is displayed 3 If you select color change use the UP and DOWN buttons to adjust the speed between SP 01 slowest and SP 99 fastest Mega Go Flood Par Operating Instructio...

Page 7: ...s the color fade is off and the fixture will now color change at the speed you have set To run the fixture in color fade reverse the instructions Set your color fade speed and set the color change spe...

Page 8: ...utton for 3 seconds to return to default settings and default running mode AUTO RUN This button will run 1 of 16 automatic programs You can scroll through the 16 programs using the and buttons You can...

Page 9: ...hannels 1 2 and 3 will not work when Channel 5 is being used Channel Value Function 1 RED 0 255 0 100 2 GREEN 0 255 0 100 3 BLUE 0 255 0 100 4 MASTER DIMMER 0 255 0 100 5 0 255 COLOR MACROS See 1 Chan...

Page 10: ...vity control will start working after Channel 5 is past the DMX value of 31 Channel Value Function 1 RED 0 255 0 100 2 GREEN 0 255 0 100 3 BLUE 0 255 0 100 4 0 255 COLOR MACROS See 1 Channel DMX mode...

Page 11: ...shortens the life of the battery Example If b050 is displayed the battery is at half life If b025 is displayed the battery is at 25 life NOTE When the battery is charging or if the battery life is be...

Page 12: ...plied with products described above Except to the extent prohibited by applicable law all implied warranties made by ADJ Products LLC in connection with this product including warranties of merchantab...

Page 13: ...ADJ Products LLC www adj com Mega Go Flood Par User Manual Page 26 ADJ Products LLC www adj com Mega Go Flood Par User Manual Page 25 Mega Go Flood Par Notes Mega Go Flood Par Notes...

Page 14: ...Mode 3 Channel Mode 4 Channel Mode 5 Channel Mode 6 Channel Mode 7 Channel Mode Warranty 3 Year 1 095 days Limited Warranty See Warranty page for details Please Note Specifications and improvements in...

Reviews: